Schmalz SCPMc Series Скачать руководство пользователя страница 3

Navigation is divided into three menus:

The main menu: for standard applications

The Extended Functions (EF) menu: for applications with special requirements

The Info menu (INF): for reading out system data such as counters, the software version, etc.

The following information can be shown on the display:

The current vacuum measurement value

The selected menu item

The settings

Error messages in the form of error codes

The operating menu’s home screen shows the currently measured vacuum level in the selected display unit. The
measured value is displayed as positive compared to the ambient air pressure.

4.1  Displaying the Basic Settings (Slide Show)

When you press the 

 button from the home screen, the following parameters are automatically displayed one

after the other on the display (slide show):

The vacuum unit

The value of switching point SP1

The value of reset point rP1

The value of switching point SP2

The supply voltage US

The display cycle returns to the vacuum display after a complete cycle or can be canceled at any time by pressing
any button.

4.2  Functions in the Main Menu

The following table shows an overview of the display codes and parameters in the main menu:

Display

code

Parameter

Explanation

5P1

Switching point 1

Value at which the control function deactivates
(only active if [

ctr

] = [

on

])

rP1

Reset point 1

Reset value 1 for the control function

5P2

Switching point 2

Switching value for the “Parts control” signal

rP2

Reset point 2

Reset value 2 for the “Parts control” signal

tbL

Blow off time

Blow off time setting for time-controlled blow off (only active if value
> 0)

CAL

Zero-point adjustment
(calibration)

Calibrate vacuum sensor, zero point = ambient pressure

EF

Extended functions

Open the “Extended Functions” submenu

1mF

Information

Open the “Information” submenu

1nc

Incorrect

The entered value is not within the permissible value range.
This is an informational message that appears if incorrect information is
entered.

4.3  Changing the Parameters of the Main menu

If you wish to change values, e.g. the switching points, you have to enter the new value digit by digit.

1. Use the 

 button to select the desired parameter.

2. Confirm using the 

 button.

ð

The currently set value is displayed and the first digit flashes.

3. Use the 

 button to change the value. The value increases by 1 each time the button is pressed. After 9,

the counter goes back to 0 when the 

 button is pressed.

EN-US · 30.30.01.02085 · 00 · 06/19