1 Ejector Structure
8
1
2
3
4
6
7
5
4.1
4.2
1
Compressed air connector (marking 1)
2
Vacuum connector (marking 2)
3
Operating and display elements
4
4.1 M8 electrical connector, 6-pole
4.2 JST electrical connector, 5-pole
5
Optional: Compressed air connector for exter-
nal blow off EB (marking 1A)
6
Silencer (marking 3)
7
Valve screw for blow off volume flow
8
2x mounting hole
2 General Parameters
Parameter
Type
Symbol
Limit value
Unit
Note
min.
typ.
max.
Working tempera-
ture
T
amb
0
—
50
° C
—
Storage tempera-
ture
T
Sto
-10
—
60
° C
—
Humidity
H
rel
10
—
85
% r.h.
Free from condensation
Degree of protec-
tion
—
—
—
IP40
—
—
Operating pressure
(flow pressure)
03
P
2
4
6
bar
—
05, 07 and
10
P
3
4
6
bar
—
Operating medium
Air or neutral gas, filtered to 5 µm, without oil, class 3-3-3 compressed air quality in acc.
with ISO 8573-1
3 Electrical Parameters
Supply voltage
DC 24 V ± 10% (PELV
1)
)
Polarity reversal protection
Yes
Current consumption
(at 24 V)
—
Typical current consumption
Max. current consumption
SCPMc – xx – NC
50 mA
70 mA
SCPMc – xx – NO
75 mA
115 mA
1)
The power supply must correspond to the regulations in accordance with EN60204 (protected extra-low voltage).
4 Operating and Menu Concepts
The ejector is operated using two buttons on the foil keypad:
MENU BUTTON
PLUS BUTTON
2 / 6
EN-US · 30.30.01.02085 · 00 · 06/19