![Schmalz ROB-SET Plus ECBPMi UR Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/schmalz/rob-set-plus-ecbpmi-ur/rob-set-plus-ecbpmi-ur_quick-start-manual_1212936019.webp)
•
(5e)
Set the configuration as default via the
icon.
5e
•
The device is now successfully set up.
(6)
Use the “Manual Mode” buttons in the “Installation > URCaps > Schmalz Gripper” menu to test the grip-
per on a workpiece.
6
7 Setting the Desired Vacuum and “Part Present Value”
ECBPMi Plus connected (see Configuration Status
Connected section)
•
(10)
Set the desired target vacuum value for the gripper with the “Desired Value” slider.
•
(11)
You can check whether your workpiece was gripped using “Part Present Value”.
If the current vacuum value is above the set “Part Present Value” limit value, the variable PartPresent is acti-
vated => workpiece gripped.