3
SCHLETTER SOLAR GMBH
RAPIDPRO MODULE CLAMP INSTALLATION GUIDE
TOOLS NEEDED
Screwdriver with Bit TX-drive T40 bit holder
TIGHTENING TORQUE
Screw connections M8 : 15 Nm
SAFETY INSTRUCTIONS
Planning, installation and commissioning of the solar power system must only be performed
by qualified technical personnel. Improper execution can result in damage to the system and
premises and endanger persons.
Falling hazard! Working on the roof as well as ascending -
and descending poses a risk of
falling. It is vital to observe accident prevention regulations and use appropriate fall protec-
tion equipment.
PV mounting systems do not meet the existing normative requirements for
climbing aids or fall protection measures. They are therefore neither suitable as climbing
aids nor as fall protection and must not be used for these purposes.
Injury hazard! Falling objects pose a risk of injury to people. Prior to installation, set up
barriers in the hazard area to warn people nearby.
Break hazard! PV modules may be damaged if stepped on or if handled inappropriately.
Electrical current hazard! Installation and maintenance of the PV modules must only be
performed by qualified technical personnel. Observe the safety instructions issued by the PV
module manufacturer!
RAPIDPRO MODULE CLAMP | V1 | INSTALLATION GUIDE | 202102
SCHLETTER SOLAR GMBH | SUBJECT TO CHANGES
Содержание RAPIDPRO