background image

Safety Switching Devices

Emergency-Stop Relay

PI 0067-0703 E

SNO 2012

6/6

Assembly

A

Set the guide (1), of the unit  on to the top - hat rail (2) at a slight angle.(DIN rail: 35 mm according to
EN 50022).

B

Press the unit onto the DIN rail, until the latch (3) snaps into place

Disassembly

C

Insert a screw driver into the latch.

D

Release the unit by turning or levering the screw driver.

E

Tilt the unit. Remove the unit from the DIN rail.

Dimension Diagram

Subject to Change

SCHLEICHER Electronic
GmbH & Co. KG
Pichelswerderstraße 3-5
D-13597 Berlin

Ph +49.30.33005.0
Fx +49.30.33005.344
H49.30.33005.304

www.schleicher-electronic.com
[email protected]