background image



P516-485

1

Prepare the Nexia Bridge for Enrollment. Choose and follow the easiest option for you shown below.

Battery powered Bridge:

•  Disconnect Ethernet and power to the Bridge.
•  Install a new, high-quality 9-volt battery into the Bridge.
•  Move the Bridge to within 6 feet (1.8 meters) of the Sensor. Keep the Bridge in this position during the entire enrollment process.

AC powered Bridge:

•  Move the Sensor to the Nexia Bridge for enrollment.
•  Keep the Sensor within 6 feet (1.8 meters) of the Nexia Bridge during the entire enrollment process.

For more information, refer to the Nexia Bridge User Guide.

2

Activate and Enroll the Sensor

a. 

Press and release the “+” button on the Bridge. The orange LED 
will blink slowly to indicate enrollment mode. 

The Bridge will 

remain in enrollment mode for 30 seconds before timeout.

b. 

Remove the Sensor’s plastic pull tab to activate battery power 
and start the Sensor’s enrollment mode. The Sensor’s LED will 
blink.

 

! If the plastic tab is already removed, then remove the 
battery for ten (10) seconds and replace the battery (shown, 
right) to restart enrollment mode.

c. 

The orange LED on the Bridge will blink rapidly when enrollment 
begins. The Bridge and Sensor LEDs will light solid to indicate 
successful enrollment.

 

! If the Bridge LED never blinks rapidly and enrollment mode 
times out (after 30 seconds), then repeat steps a-c.

+

 

 

ATTENTION! Electrostatic Sensitive!

Avoid touching the antenna or circuit board when handling the 
battery.

Orange 

LED

+

Button

b.

a.

Door/Window Sensor Installation Instructions

Product Overview

•  Z-Wave™ enabled device which provides open/closed

position status

•  Transmits open/closed status
•  Reports tamper condition when cover is open

Product Specifi cations

•  For indoor use only
•  Operating frequency: 908.42 MHz
•  Operation range: Up to 100 feet (30.5 meters) line-of-sight
•  Operating temperature: 0° – 49°C, 32° – 120°F (ambient

temperature)

•  Battery type required: 3V Lithium CR123A
•  Battery life approximately 3 years

 

Caution:  This product is dependent upon self-monitoring and uses Z-Wave 

technology to communicate data wirelessly to other products.  This product is not 
monitored by a third party and radio communication (including Z-Wave) is not 100% 
reliable.  Therefore, this product should not be solely relied upon for the protection of
life or valuables.

Caution:  Exposure to water will damage this product and can make it inoperable.

 

Note: Performance of this product is dependent upon proper installation, and product 

will not perform as intended if not installed pursuant to these instructions.

DO NOT plug in Ethernet or power before enrolling!

Optional

Installation Tool

Содержание P516-485

Страница 1: ...solid to indicate successful enrollment If the Bridge LED never blinks rapidly and enrollment mode times out after 30 seconds then repeat steps a c ATTENTION Electrostatic Sensitive Avoid touching the antenna or circuit board when handling the battery Orange LED Button b a Door Window Sensor Installation Instructions Product Overview Z Wave enabled device which provides open closed position status...

Страница 2: ...r the browser to refresh LIGHTING MODULES CAMERAS CLIMATE SECURITY SENSORS CLOSED Setup Device New Sensor 3 Sensors Locks Security Sensors New Sensor Sensor Type Door Alerts Alert when opened Alert when closed Save Changes Cancel s s C CLOSED OPEN Sensors Locks my sensor Sensors Locks my sensor CLOSED OPEN Sensors Locks my sensor Sensors Locks my sensor Figure 1 Figure 2 Figure 3 Door Sensor Windo...

Страница 3: ...on the bracket Left hand door OR Right hand door OR The top of the magnet must be within 6 mm of the arrow on the Sensor as shown above Install the magnet no more than 19 mm away from the Sensor for optimal performance Install the Magnet with screws a Remove the base from the magnet b Use two 2 small screws included to attach the base of the magnet to the door or window c Press the magnet onto the...

Страница 4: ...e Bridge within 6 feet 1 8 meters of the Sensor during the entire exclusion process c Press and release the button on the Bridge d Remove the battery from the Sensor e Leave the battery out for at least ten 10 seconds f Reinstall the battery into the Sensor g Observe lights on the Bridge The orange LED will blink rapidly while exclusion is taking place Exclusion is complete when the orange LED lig...

Страница 5: ... activation du mode d inscription Le Bridge reste en mode d inscription pendant 30 secondes avant temporisation b Retirez la languette en plastique du capteur pour activer l alimentation par la pile et démarrez le mode d inscription du capteur La DEL du capteur clignote Si la languette en plastique a déjà été retirée alors retirez la pile pendant dix 10 secondes et remettez la en place pour redéma...

Страница 6: ...nsors New Sensor Sensor Type Door Alerts Alert when opened Alert when closed Save Changes Cancel s C CLOSED OPEN Sensors Locks my sensor Sensors Locks my sensor CLOSED OPEN Sensors Locks my sensor Sensors Locks my sensor Sensor de puerta Capteur de porte Sensor de ventana Capteur de fenêtre Figura Figure 1 Figura Figure 2 Figura Figure 3 4 Prueba del interruptor de manipulación opcional a Presione...

Страница 7: ...apertura hacia la izquierda Porte à ouverture à gauche OR IMPORTANTE El sensor y el imán deben estar alineados como se muestra IMPORTANT Le capteur et l aimant doivent être alignés comme illustré 6 mm máximo maximum Flecha Flèche O OU Puerta de apertura hacia la derecha Porte à ouverture à droite OR Lengüetas orientadas hacia abajo Languettes vers le bas Lengüetas orientadas hacia arriba Languette...

Страница 8: ...ange doit clignoter rapidement pendant l exclusion L exclusion est terminée lorsque la DEL orange reste fixe h Retirez la pile du capteur une fois l exclusion terminée Para más información consulte la Guía del usuario del puente Nexia S il est nécessaire de retirer un capteur du compte Nexia suivez ces étapes afin d exclure le capteur d un réseau Z Wave a Installez une pile 9 volts neuve de bonne ...

Отзывы: