![Schlage M422 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/schlage/m422/m422_installation-instructions-manual_1212618007.webp)
7
5g Align Center of Brackets Using Alignment Tool
a. Loosen two (2) innermost screws.
b. Place alignment tool over brackets.
c. Tighten all four (4) screws.
Loosen these
two screws.
Outside
5h Verify magnet adjustment.
a. Close door and verify magnets make full contact with
armatures.
b. If alignment is satisfactory, go to step 5i.
c. If further adjustment is required, repeat steps 5e through 5h.
Inside
Magnets making
full contact with
armatures
5i Prepare additional holes.
a. Install alignment tool on brackets.
b. Fully tighten four (4) screws.
c. Drill eight (8) remaining holes. Use #10-24 tap if
metal is reinforced.
Outside
Fully tighten
four screws.
5j Install eight (8) screws
a. Remove alignment tool.
b. Install and fully tighten eight (8) screws.
CAUTION
All eight screws MUST be installed for proper
operation and safety!
If you do not have enough room to securely
fasten all screws, you will need filler plates and/or
angle brackets to properly mount the magnet.
Failure to properly install the screws may lead to
injury or property damage.
Contact customer service at 1-877-671-7011.
Actual Size
Reinforced Metal
Sheet Metal