6
English
PRogRAmmINg PRoCeDuReS
»
Determine how long you want your User Codes to be BEFORE
adding any User Codes. If you change the User Code length, all
existing User Codes will be deleted!
»
Programming Mode will automatically time out after 30 seconds of
inactivity.
1.
Open the door and extend the deadbolt before beginning.
2.
If you make a mistake, press the Schlage Button to leave
Programming Mode, and then start over.
ADD uSeR CoDe
Press
Enter
6 Digit
Programming Code
Press
New 4-8 Digit
User Code
Same New
4-8 Digit User
Code
2
2 Beeps
Add another code
DeLete uSeR CoDe
Press
Enter
6 Digit
Programming Code
Press
New 4-8 Digit
User Code
Same New
4-8 Digit User
Code
2
2 Beeps
Add another code
CHANge PRogRAmmINg CoDe
Press
Enter
6 Digit
Programming Code
Press
New 6 Digit
Programming
Code
Same New
6 Digit
Programming
Code
2
2 Beeps
eNABLe VACAtIoN moDe
Press
Enter
6 Digit
Programming Code
Press
2
2 Beeps
DISABLe VACAtIoN moDe
Press
Enter
6 Digit
Programming Code
2
2 Beeps
eNABLe/DISABLe BeePeR
Press
Enter
6 Digit
Programming Code
Press
Enable: 1 Blink + 1 Beep
Disable: 2 2 Beeps
DeLete ALL uSeR CoDeS
Press
Enter
6 Digit
Programming Code
Press
Digit
Programming
Code
2
2 Beeps
L
WARNING! Removes ALL User Codes from the lock. User Codes cannot be retrieved after they are deleted!
eNABLe/DISABLe LoCk & LeAVe
Press
Enter
6 Digit
Programming Code
Press
Enable: 1 Blink + 1 Beep
Disable: 2 2 Beeps
CHANge uSeR CoDe LeNgtH
Press
Enter
6 Digit
Programming Code
Press
Desired User
Code Length
Same Desired
User Code
Length
2
2 Beeps
L
WARNING! Changing the User Code length will delete all existing User Codes! User Codes cannot be retrieved after
they are deleted!