Installation and commissioning DATAEAGLE 3XXX X-treme
Chapter 7
– Diagnostic slave
The max. response time of the slave is saved by setting the send data bit 2
(DBB2) to „1“.
Block 4: Number of retry calls (Timeout counter)
Position
Meaning
Value
Control Value
Byte 0
Transmission retries
slave 1
0 to 255
Display number (here: 4)
Byte 1
Transmission retries
slave 2
0 to 255
0: no function
1: reset counter
Byte 2
Transmission retries
slave 3
0 to 255
..
..
Byte 31
4
Feedback from display
side (here 4)
Block 5: Number of restarts due to errors (Initialisation counter)
Position Meaning
Value
Control Value
Byte 0
Number of restarts
slave 1
(transmission side)
0 to 255
Display number (here: 5)
Byte 1
Number of restarts
slave 2
(transmission side)
0 to 255
0: no function
1: reset counter
Byte 2
Number of restarts
slave 3
(transmission side)
0 to 255
..
..
Byte 31
5
Feedback from display
side (here 5)
Block 6: Number of restarts from DP side
Position Meaning
Value
Control Value
Byte 0
Number of restarts
slave 1
(DP side)
0 to 255
Display number (here: 6)
Byte 1
Number of restarts
slave 2
(DP side)
0 to 255
0: no function
1: reset counter
Byte 2
Number of restarts
slave 3
(DP side)
0 to 255
..
Byte 31
6
Feedback from display
side (here 6)