background image

Page -6-

OPERATING INSTRUCTIONS

PREPARING FOR OPERATION
   

1. Extend the shell fully and lock into place as shown in the

enclosed instructions sheet before lighting or operating the
heater.

   2.Check the heater for possible shipping damage. If any is

found, 

immediately

 notify the factory.

3. Follow all of the Safety and Operating Precautions.
4. Connect the POL fitting of hose and regulator assembly to

the propane cylinder by rotating the POL nut
counterclockwise into the propane cylinder's valve outlet and
securely tighten with a wrench.

5. Connect the hose to the heater.
6. Securely tighten all gas connections.
7. Open the cylinder's gas valve and check all gas connections

with a soap and water solution. DO NOT USE A FLAME.

START

1. WARNING:  BEFORE LIGHTING PILOT, fully close the ball

valve (turn knob fully clockwise).

2. Fully open the valve on the propane cylinder and wait 15

seconds before Step 3.

3. Depress red button on safety pilot valve admitting gas to the

heater.  Then push and release the ignition button until the
pilot lights.

4.When the pilot lights, continue to hold the button depressed

for 30 seconds, then release.

5. If pilot goes out, wait 5 minutes and repeat the lighting

procedure.

6.When the pilot remains lit, open the ball valve (turn knob

counter clockwise) to light main burner.  Partially close valve
to regulate heat output.

STOP

1. Securely close valve on the propane cylinder.
2. Continue to operate heater until all fuel in the hose has

burned.

3. Fully close the ball valve.

RESTART AFTER SAFETY SHUTDOWN

1. Securely close valve at propane cylinder.
2. Wait 5 minutes.
3. Restart following "Start" procedure.

MAINTENANCE AND STORAGE

1. The heater should be inspected before each use, and at

least annually by a qualified person.

2. Before each use, check the soft "O" ring seat at the bullnose

of the POL fitting. If the "O" ring is cut, scuffed, or otherwise
damaged, replace it with part number 6681.

3. Turn off the gas at the LP-gas supply cylinder(s) when the

heater is not in use.

4. When the heater is to be stored indoors, the connection

between the LP-gas supply cylinder(s) and the heater must
be disconnected and the cylinder(s) removed from the
heater and stored out of doors and in accordance with
Chapter 5 of the standard for Storage and Handling of
Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B149.1,
Natural Gas and Propane Installation Code.

SERVICING

A hazardous condition may result if a heater is used that has
been modified or is not functioning properly. When the heater is
working properly:

* The flame is contained within the heater.
* The flame is essentially blue with perhaps some yellow

tipping.

* There is no strong disagreeable odor, eye burning or other

physical discomfort.

* There is no smoke or soot internal or external to the heater.
* There are no unplanned or unexplained shut downs of the

heater.

The parts lists and exploded view show the heater as it was
constructed. Do not use a heater which is different from that
shown. In this regard, use only the hose, regulator and cylinder
connection fitting (called a POL fitting) supplied with the heater.

IMPORTANT

 Match the color stripe on the hangtag attached to

the hose assembly with the color on the label located near the
propane inlet fitting on the heater.

 

Do not use alternates. For

this heater, the regulator must be set as shown in
"specifications". If there is any uncertainty about the regulator
setting, have it checked.

A heater which is 

not 

working right must be repaired, but 

only

 by

a trained, experienced service person. To find the service center
closest to you, visit our website at www.scheuco.com.or call
(888) 619-7060.

You may also obtain in-warranty or out-of-warranty service by
taking the product to your local service center.

In-warranty products will be repaired with no charge for either
parts or labor. Please include a brief statement indicating date,
place of purchase, the nature of the problem and proof of
purchase.

Out-of-warranty products will be repaired with a charge for parts
and labor.

Models

80C/SPC-80C,    200C/SPC-200C

Содержание 200C/SPC-200C

Страница 1: ...aters com warranty 2002 Scheu Products Company OWNERS MANUAL CONVECTION CONSTRUCTION HEATERS Models 80C SPC 80C 200C SPC 200C RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE TABLE OF CONTENTS HEATER SPECIFICATIONS 2 WARNINGS 2 OPERATING PRECAUTIONS 3 SAFETY PRECAUTIONS 3 ODOR FADE WARNING 4 CAUTION SHELL EXTENSION INSTRUCTIONS 5 OPERATING INSTRUCTIONS 6 SERVICING 6 SIZE AND CAPACITY OF PROPANE CYLI...

Страница 2: ...e of Gas For use with Propane Only Gas Supply Pressure to regulator Maximum Bottle Pressure Minimum 80C SPC 80C 5 psig 34 5 kPa Minimum 200C series 15 psig 103 kPa regulator out 80C SPC 80C 11 W C 2 74 kPa 200C series 10 psig 68 9 kPa Ignition Piezo Ignitor 200C SPC 200C is manual MinimumAmbientTemp Rating 0 F 17 8 C Model 80CSERIES 200CSERIES Rating 30 000 80 000 Btu hr 75 000 200 000 Btu hr 8 79...

Страница 3: ...f there is any question about vapor withdrawal ask your propane dealer 6 Mount the propane cylinders vertically shutoff valve up Secure them from falling or being knocked over and protect them from damage 7 Locate propane containers at least USA 7 ft 2 13m for 80 series and 9 ft 2 7m for 200C series Canada 10 ft 3m from the heater and do not direct exhaust toward containers 8 IMPORTANT Use only th...

Страница 4: ...ar odor Odors present in animal confinement buildings can mask fuel gas odor The odorant in propane LP gas and natural gas is colorless and the intensity of its odor can fade under some circumstances If there is an underground leak the movement of gas through the soil can filter the odorant Propane LP gas odor may differ in intensity at different levels Since Propane LP gas is heavier than air the...

Страница 5: ...SURE CLIP GOES INTO SLOT IN LOWER SHELL 3 PLACES STEP3 LIFTOUTERSHELLUNTILALL THREECLIPSINGAGESLOTSINLOWER SHELL WHENTHISHAPPENS THESCREW HOLESWILLLINEUP LOCKSHELLSTOGETHER ANDCLIPSIN PLACEWITH SCREWS IN EACH CLIP 3SCREWS TOTAL STEP4 LOCKTHECLIPINTOPLACEWITH3 SCREWSASSHOWN THEHEATERMUSTNOTBE OPERATEDUNLESSTHEOUTERSHELLIS PROPERLYEXTENDEDANDFULLYLOCKED INTOPLACE CAUTION NEVER IGNITE AND OR RUN THIS...

Страница 6: ...the gas at the LP gas supply cylinder s when the heater is not in use 4 When the heater is to be stored indoors the connection between the LP gas supply cylinder s and the heater must be disconnected and the cylinder s removed from the heater and stored out of doors and in accordance with Chapter 5 of the standard for Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 and CSA B149 1 Na...

Страница 7: ...aters To use the chart 1 Select the lowest air temperature expected at the bottom of the chart 2 Move straight up to time of operation desired left side of chart 3 Read the cylinder size required All heaters should have full cylinders good air circulation no frost on cylinders 80C SPC 80C 200C SPC 200C Models 80C SPC 80C 200C SPC 200C ...

Страница 8: ... 1 4 MPT 1 8761 Manual Operating Instructions 1 19 6255 Regulator 1 20 8654 Valve Ball 1 21 6473 Piezo Ignitor 1 22 6503 Nut Hex 1 2 28 TE Valve 1 23 7172 Ftg Elbow Female 1 4 FPTx 3 8 FLR 3 24 8162 External Retaining Ring 1 25 7161 Piezo Nut 1 26 7652 Electrode w 7 wire 1 27 4293 Heat Shield 1 28 8644 Pilot Orifice 1 29 6689 Washer Flat 1 16 SAE 1 30 8187 Ftg Elbow 1 8 FPT x 1 4 CPSN 1 31 2237 Lo...

Страница 9: ...1 18 6252 POL Excell Flow 1 19 6256 Regulator 1 20 8654 Valve Ball 1 21 6473 Piezo Ignitor 225 VCA VCB Only 1 22 6503 Nut Hex 1 2 28 TE Valve 1 23 7172 Ftg Elbow Female 1 4 FPTx3 8 FLR 2 24 8162 External Retaining Ring 1 25 7161 Piezo Nut 1 26 7652 Electrode w 7 Wire 1 27 4293 Heat Shield 1 28 8647 Pilot Orifice 1 29 6689 Washer Flat 9 16 SAE 1 30 8187 Fitting Elbow 1 8 FPTx1 4 CPSN 1 31 2238 Lowe...

Страница 10: ... php scheuco com Include your name address and telephone number and include details concerning the claim Also supply us with the purchase date and the name and address of the dealer from whom you purchased our product The foregoing is the full extent of the responsibility of the Company There are no other warranties express or implied Specifically there is no warranty of fitness for a particular p...

Страница 11: ...Store Hardware Home Center Warehouse Retailer Discount Store Farm Supply Contractor s Supply Other Your Preferences How did you learn about our heater Advertising Relative friend Store display Previously owned heater Other What prompted you to buy your heater Sudden cold weather Emergency backup heat Heater on sale Replaces old model Hard to heat location Construction project Other Where will you ...

Страница 12: ...technical support customer service and warranty registration at WWW ALLPRO HEATERS COM forAll Pro products orWWW UNVERISAL HEATERS COM for Universal products SCHEU PRODUCTS COMPANY INC ATTN MARKETINGDEPARTMENT 8855 BAKERAVENUE RANCHO CUCAMONGA CA 91730 ...

Отзывы: