background image

Page -2-

 GENERAL HAZARD WARNING:

FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN
DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN,
ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.

ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.

IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT
THE MANUFACTURER.

 WARNING:  FIRE, BURN, INHALATION, AND EXPLOSION HAZARD.  KEEP SOLID COMBUSTIBLES, SUCH AS

BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED
BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE
COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN
CHEMICALS.

HEATER SPECIFICATIONS

Type of Gas:

For use with Propane Only

Gas Supply Pressure

to  regulator

Maximum:  Bottle Pressure

Minimum:  80C-/SPC-80C = 5 psig (34.5 kPa)
Minimum: 200C series = 15 psig (103 kPa)

regulator out

80C/SPC-80C = 11" W.C. (2.74 kPa)

200C series = 10 psig (68.9 kPa)

Ignition:

Piezo Ignitor  (200C/SPC-200C is manual)

Minimum Ambient Temp. Rating

0°F  (-17.8°C)

Model:

80C SERIES

200C SERIES

Rating:

30,000 - 80,000 Btu/hr

75,000 - 200,000 Btu/hr

(8.79 - 23.4 kW)

(22.0 - 58.6 kW)

Fuel Consumption:

1.4 to 3.7 #/hr

3.5 - 0.3 #hr

(.74 – 1.80 kg/hr)

(1.44 - 4.32 kg/hr)

Fuel Orifice Port No.:

6

6

Fuel Orifice Port Size:

0.0472"

0.0320"

(1.20mm)

(.813mm)

WARNING: NOT FOR HOME OR RECREATIONAL VEHICLE USE

WARNINGS

YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASE

READ THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER.

Scheu Products Company, Incorporated

Mail: P.O. Box 250, Upland, CA 91785

Plant: 8855 Baker Ave., Rancho Cucamonga, CA 91730

Telephone: 800-325-7057

www.scheuco.com

[email protected]

8761

September 2003

Models

80C/SPC-80C,    200C/SPC-200C

ANSI Z83.7/CGA 2.14-2000

Содержание 200C/SPC-200C

Страница 1: ...aters com warranty 2002 Scheu Products Company OWNERS MANUAL CONVECTION CONSTRUCTION HEATERS Models 80C SPC 80C 200C SPC 200C RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE TABLE OF CONTENTS HEATER SPECIFICATIONS 2 WARNINGS 2 OPERATING PRECAUTIONS 3 SAFETY PRECAUTIONS 3 ODOR FADE WARNING 4 CAUTION SHELL EXTENSION INSTRUCTIONS 5 OPERATING INSTRUCTIONS 6 SERVICING 6 SIZE AND CAPACITY OF PROPANE CYLI...

Страница 2: ...e of Gas For use with Propane Only Gas Supply Pressure to regulator Maximum Bottle Pressure Minimum 80C SPC 80C 5 psig 34 5 kPa Minimum 200C series 15 psig 103 kPa regulator out 80C SPC 80C 11 W C 2 74 kPa 200C series 10 psig 68 9 kPa Ignition Piezo Ignitor 200C SPC 200C is manual MinimumAmbientTemp Rating 0 F 17 8 C Model 80CSERIES 200CSERIES Rating 30 000 80 000 Btu hr 75 000 200 000 Btu hr 8 79...

Страница 3: ...f there is any question about vapor withdrawal ask your propane dealer 6 Mount the propane cylinders vertically shutoff valve up Secure them from falling or being knocked over and protect them from damage 7 Locate propane containers at least USA 7 ft 2 13m for 80 series and 9 ft 2 7m for 200C series Canada 10 ft 3m from the heater and do not direct exhaust toward containers 8 IMPORTANT Use only th...

Страница 4: ...ar odor Odors present in animal confinement buildings can mask fuel gas odor The odorant in propane LP gas and natural gas is colorless and the intensity of its odor can fade under some circumstances If there is an underground leak the movement of gas through the soil can filter the odorant Propane LP gas odor may differ in intensity at different levels Since Propane LP gas is heavier than air the...

Страница 5: ...SURE CLIP GOES INTO SLOT IN LOWER SHELL 3 PLACES STEP3 LIFTOUTERSHELLUNTILALL THREECLIPSINGAGESLOTSINLOWER SHELL WHENTHISHAPPENS THESCREW HOLESWILLLINEUP LOCKSHELLSTOGETHER ANDCLIPSIN PLACEWITH SCREWS IN EACH CLIP 3SCREWS TOTAL STEP4 LOCKTHECLIPINTOPLACEWITH3 SCREWSASSHOWN THEHEATERMUSTNOTBE OPERATEDUNLESSTHEOUTERSHELLIS PROPERLYEXTENDEDANDFULLYLOCKED INTOPLACE CAUTION NEVER IGNITE AND OR RUN THIS...

Страница 6: ...the gas at the LP gas supply cylinder s when the heater is not in use 4 When the heater is to be stored indoors the connection between the LP gas supply cylinder s and the heater must be disconnected and the cylinder s removed from the heater and stored out of doors and in accordance with Chapter 5 of the standard for Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 and CSA B149 1 Na...

Страница 7: ...aters To use the chart 1 Select the lowest air temperature expected at the bottom of the chart 2 Move straight up to time of operation desired left side of chart 3 Read the cylinder size required All heaters should have full cylinders good air circulation no frost on cylinders 80C SPC 80C 200C SPC 200C Models 80C SPC 80C 200C SPC 200C ...

Страница 8: ... 1 4 MPT 1 8761 Manual Operating Instructions 1 19 6255 Regulator 1 20 8654 Valve Ball 1 21 6473 Piezo Ignitor 1 22 6503 Nut Hex 1 2 28 TE Valve 1 23 7172 Ftg Elbow Female 1 4 FPTx 3 8 FLR 3 24 8162 External Retaining Ring 1 25 7161 Piezo Nut 1 26 7652 Electrode w 7 wire 1 27 4293 Heat Shield 1 28 8644 Pilot Orifice 1 29 6689 Washer Flat 1 16 SAE 1 30 8187 Ftg Elbow 1 8 FPT x 1 4 CPSN 1 31 2237 Lo...

Страница 9: ...1 18 6252 POL Excell Flow 1 19 6256 Regulator 1 20 8654 Valve Ball 1 21 6473 Piezo Ignitor 225 VCA VCB Only 1 22 6503 Nut Hex 1 2 28 TE Valve 1 23 7172 Ftg Elbow Female 1 4 FPTx3 8 FLR 2 24 8162 External Retaining Ring 1 25 7161 Piezo Nut 1 26 7652 Electrode w 7 Wire 1 27 4293 Heat Shield 1 28 8647 Pilot Orifice 1 29 6689 Washer Flat 9 16 SAE 1 30 8187 Fitting Elbow 1 8 FPTx1 4 CPSN 1 31 2238 Lowe...

Страница 10: ... php scheuco com Include your name address and telephone number and include details concerning the claim Also supply us with the purchase date and the name and address of the dealer from whom you purchased our product The foregoing is the full extent of the responsibility of the Company There are no other warranties express or implied Specifically there is no warranty of fitness for a particular p...

Страница 11: ...Store Hardware Home Center Warehouse Retailer Discount Store Farm Supply Contractor s Supply Other Your Preferences How did you learn about our heater Advertising Relative friend Store display Previously owned heater Other What prompted you to buy your heater Sudden cold weather Emergency backup heat Heater on sale Replaces old model Hard to heat location Construction project Other Where will you ...

Страница 12: ...technical support customer service and warranty registration at WWW ALLPRO HEATERS COM forAll Pro products orWWW UNVERISAL HEATERS COM for Universal products SCHEU PRODUCTS COMPANY INC ATTN MARKETINGDEPARTMENT 8855 BAKERAVENUE RANCHO CUCAMONGA CA 91730 ...

Отзывы: