background image

IMPORTANT SAFETY INSTRUCTIONS

THE LIGHTNING FLASH WITH ARROWHEAD SYMBOL, WITHIN AN EQUILATERAL TRIANGLE, IS INTENDED TO ALERT THE USER TO THE PRESENCE OF 

UNINSULATED “DANGEROUS VOLTAGE” WITHIN THE PRODUCT ENCLOSURE THAT MAY BE OF A SUFFICIENT MAGNITUDE TO CONSITUTE A RISK OF 

ELECTRIC SHOCK TO PERSONS.

THE EXCLAMATION POINT WITHIN AN EQUILATERAL TRIANGLE, IS INTENDED TO ALERT THE USER TO THE PRESENCE OF IMPORTANT OPERATING AND 

MAINTENANCE INSTRUCTIONS IN THE LITERATURE ACCOMPANYING THE PRODUCT.

WARNING

TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK 

DO NOT EXPOSE THE APPLIANCE TO RAIN OR HUMIDITY

1) Read these instructions.

2) Keep these instructions.

3) Heed all warnings.

4) Follow all instructions.

5) Do not use this apparatus near water.

6) Clean only with dry cloth.

7) Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (inclu-

ding amplifiers) that produce heat.

9) Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two bla-

des with one wider than the other. A grounding type plug has two blades and a third grounding prong. The 

wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, 

consult an electrician for replacement of the obsolete outlet.

10) Protect the power cord from being walked on or pinched particularly at plugs, convenience recepta-

cles, and the point where they exit from the apparatus.

11) Only use attachments/accessories specified by the manufacturer.

12) Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the 

apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury 

from tip-over.

13) Unplug this apparatus during lightning storms or when unused for long periods of time.

14) Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been 

damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects 

have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate nor-

mally, or has been dropped.

Содержание Jam 100

Страница 1: ...JAM 100 Combo amplifier for acoustic instruments ...

Страница 2: ... safety purpose of the polarized or grounding type plug A polarized plug has two bla des with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being wal...

Страница 3: ...ld result in feedback Larsen effect and ultimate damage to your device Only use the original connection cables if supplied with the device Otherwise this could prove both costly and inconvenient To completely disconnect this device from the AC mains remove the power cable plug from the mains socket When cleaning do not use solvents e g acetone or alcohol These could damage the external finish and ...

Страница 4: ...nest sound quality 3 independent channels plus a CD input Phono connection enable the simultaneous connection of several instruments Channels 1 and 2 offer XLR connections with phantom power as well as Hi Z line inputs Other features include 3 band EQ digital reverb and an intuitive compact control surface enabling easy set up and adjustment ...

Страница 5: ...l depends on the EFF RTN volume control 1 5 VOL ch 1 2 3 4 This rotary control sets the channel volume sent to the Master 1 6 LINE IN High Z Low Z ch 3 Unbalanced line inputs with double sensitivity the HI plug is dedicated to low level audio signals such as electric guitar and bass acoustic guitars etc The use of both plugs is dedicated to high level signals such as keyboards music player etc 1 7...

Страница 6: ...mic microphones along with some preamps can be safely phantom powered In certain cases however phantom power can cause damage to a device This tends to occur with unbalanced microphones preamps or stompboxes that have been modified for balanced XLR use If in doubt please contact us to check the compatibility of your audio device before using the amplifier The LED indicates when the Phantom Power i...

Страница 7: ...nce LINE IN Connector Sensitivity Impedance OUTPUTS REC OUT Connector Level Impedance D I OUT Connector Level Impedance 60 Hz 20 kHz 89 dB 108 dB 6 Dome 1 Active 24 dB octave Bass reflex Birch laminated 2 way Bi amp 70 W 30 W 11 Kg 272 x 290 x 362 mm XLR balanced 35 dB 1K ohm Jack 6 3 mm RCA unbalanced 18 dB Jack 10 dB RCA 10 Kohm RCA unbalanced 10 dBu 1 kohm XLR balanced 20 dBu 470 ohm ...

Страница 8: ...ARE NOT COVERED UNDER RIGHTS OBTAINED THROUGH OUR WARRANTY POLICY OR THAT OF INTERNATIONALLY RECOGNIZED TERMS AND CONDITIONS SCHERTLER SAIS CONSTANTLYAIMING TO IMPROVE ITS RANGE OF PRODUCTS THEREFORE SCHERTLER SA RESERVES THE RIGHT TO AMEND PRODUCT SPECIFICATIONS WITHOUT NOTICE THE SCHERTLER NAME LOGO ARE REGISTERED TRADE NAMES TRADEMARKS OF SCHERTLER SA SWITZERLAND All SCHERTLER PRODUCTS ARE OF P...

Отзывы: