IMPORTANT SAFETY INSTRUCTIONS

THE LIGHTNING FLASH WITH ARROWHEAD SYMBOL, WITHIN AN EQUILATERAL TRIANGLE, IS INTENDED TO ALERT THE USER TO THE PRESENCE OF 

UNINSULATED “DANGEROUS VOLTAGE” WITHIN THE PRODUCT ENCLOSURE THAT MAY BE OF A SUFFICIENT MAGNITUDE TO CONSITUTE A RISK OF 

ELECTRIC SHOCK TO PERSONS.

THE EXCLAMATION POINT WITHIN AN EQUILATERAL TRIANGLE, IS INTENDED TO ALERT THE USER TO THE PRESENCE OF IMPORTANT OPERATING AND 

MAINTENANCE INSTRUCTIONS IN THE LITERATURE ACCOMPANYING THE PRODUCT.

WARNING

TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK 

DO NOT EXPOSE THE APPLIANCE TO RAIN OR HUMIDITY

1) Read these instructions.

2) Keep these instructions.

3) Heed all warnings.

4) Follow all instructions.

5) Do not use this apparatus near water.

6) Clean only with dry cloth.

7) Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (inclu

-

ding amplifiers) that produce heat.

9) Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two bla

-

des with one wider than the other. A grounding type plug has two blades and a third grounding prong. The 

wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, 

consult an electrician for replacement of the obsolete outlet.

10) Protect the power cord from being walked on or pinched particularly at plugs, convenience recepta

-

cles, and the point where they exit from the apparatus.

11) Only use attachments/accessories specified by the manufacturer.

12) Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the 

apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury 

from tip-over.

13) Unplug this apparatus during lightning storms or when unused for long periods of time.

14) Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been 

damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects 

have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate nor

-

mally, or has been dropped.

Содержание Arthur ART48 STEREO IN

Страница 1: ...ACOUSTIC FIDELITY arthur ART48 STEREO IN USER MANUAL Assembling instruction on ART48 L Rmast manual Version 2017 V2 ...

Страница 2: ...ould result in feedback Larsen effect and ultimate damage to your device Only use the original connection cables if supplied with the device Otherwise this could prove both costly and inconvenient To completely disconnect this device from the AC mains remove the power cable plug from the mains socket When cleaning do not use solvents e g acetone or alcohol These could damage the external finish an...

Страница 3: ... safety purpose of the polarized or grounding type plug A polarized plug has two bla des with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being wal...

Страница 4: ...s such as keyboards and Midi devices 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 1 2 9 9 9 9 9 9 9 9 9 9 9 9 R L 0 direct outs UNITY UNITY gain gain PFL L post pre Stereo Jack R L pre hi low BUS PFL AUX 3 AUX 2 AUX 1 all pots and sw itches in blu color all plugs and bus in red color Fader L ON post AUX 2 AUX 3 AUX 1 R L 48V Fader R ON PFL R AUX 2 AUX 3 AUX 1 gain 15dB t...

Страница 5: ...er advantage of these phone plugs is that you can connect an unbalanced music signal for example from a keyboard via a simple guitar jack Although this stereo input unit is intended to accommodate nominal line level signals the input amp s sensitivity can be adjusted from 15 dBu to 24 dBu using the GAIN knobs 4 Left and right input channels can be separately adjusted Furthermore by depressing the ...

Страница 6: ... of the Pre Post buttons 9 located near the respective AUX level controls If a button is not depressed orange light it means that the signal will arrive post fade When in this position the relevant auxiliary level will obviously be controlled by its level knob but the final outcome will also be influenced by the channel fader s position This is very useful when driving a reverb unit for example wh...

Страница 7: ...ed in this case the signal from the voice channel Note The PFL section still runs if the CHANNEL ON button is deactivated white light L R FADER SECTION 11 The channel fader and its associated functionality is probably the most important part of the output process In most cases the signal going through here will be mixed in the L R Master and will appear on the main L R outputs that drive the recor...

Страница 8: ... THE SCHERTLER NAME LOGO ARE REGISTERED TRADE NAMES TRADEMARKS OF SCHERTLER SA SWITZERLAND All SCHERTLER PRODUCTS ARE OF PROPRIETARY TECHNOLOGY AND COVERED BY ONE OF MORE WORLDWIDE PATENTS TECHNICAL SPECS Input impedance Maximum input level Maximum output level through L R Sensitivity accordingly to Gain Total Gain through L R Frequency response 3dB Low EQ High EQ Equivalent input noise EIN Distor...

Отзывы: