www.scheppach.com
GB | 27
12.4.1 Releasing overpressure
Release overpressure in the compressor by switching
off the compressor and using up the compressed air
still in the pressure vessel, e.g. with a compressed air
tool running at idle or with an air blow gun.
12.5 Ordering spare parts
Please provide the following information when ordering
replacement parts:
• Device type
• Device article number
• Device ID number
• Replacement part number of the required replace-
ment part
12.6 Service information
With this product, it is necessary to note that the follow-
ing parts are subject to natural or usage-related wear,
or that the following parts are required as consuma-
bles.
Wearing parts*:
Cylinder, piston, piston rings
* may not be included in the scope of supply!
Spare parts and accessories can be obtained from our
service centre. To do this, scan the QR code on the
cover page.
13. Disposal and recycling
Notes for packaging
The packaging materials are
recyclable. Please dispose of
packaging in an environmentally
friendly manner.
Notes on the electrical and electronic equipment
act [ElektroG]
Waste electrical and electronic equipment
does not belong in household waste, but
must be collected and disposed of sepa-
rately!
• Old batteries or rechargeable batteries that are
not permanently installed in the old unit must be
removed before handing them in! Their disposal is
regulated by the battery act.
• Owners or users of electrical and electronic devices
are legally obliged to return them after use.
• The end user is responsible for deleting their per-
sonal data from the old device being disposed of!
12.2 Pressure vessel maintenance /
Condensate (Fig. 1)
m
ATTENTION!
To ensure a long service life for the pressure ves-
sel (4), drain off the condensate after each use by
opening the drain screw (11).
Release the vessel pressure beforehand (see 10.4.1).
The drain screw is opened by turning it counterclock-
wise (when looking at the screw on the bottom of the
compressor) so that the condensate can be completely
drained out of the pressure vessel.
Then close the drain screw again (turn clockwise).
Check the pressure vessel for rust and damage each
time before use.
The compressor shall not be operated if the pressure
vessel is damaged or rusty.
If you discover damage, please contact the customer
service workshop.
12.3 Safety valve (Fig. 2)
The safety valve (12) is set to the maximum permissi-
ble pressure of the pressure vessel. It is not permit-
ted to adjust the safety valve or to remove the con-
nection lock (12.2) between the drain nut (12.1) and
its cap (12.3).
In order for the safety valve to function properly when
needed, it must be actuated every 30 operating hours
and at least 3 times a year. Turn the perforated drain
nut (12.1) anti-clockwise to open it, then pull the valve
stem outwards by hand via the perforated drain nut
(12.1) to open the safety valve outlet. Now, the valve
audibly releases air. Then turn the drain nut clockwise
again to tighten.
12.4 Storage
m
ATTENTION!
Pull out the mains plug and ventilate the equip-
ment and all connected pneumatic tools. Store the
compressor in such a way that it cannot be used by
unauthorised persons.
m
ATTENTION!
Store the compressor only in a dry location which
is not accessible to unauthorised persons. Always
store upright, never tilted!