13. Cleaning
Danger!
Disconnect the mains plug before carrying out any
cleaning work.
• Keep protective devices, air vents and the motor
housing as free of dust and dirt as possible. Rub
the device clean with a clean cloth or blow it off with
compressed air at low pressure. We recommend
that you clean the device directly after every use.
• Clean the device at regular intervals using a damp
cloth and a little soft soap.
Do not use any cleaning
products or solvents; they could attack the plastic
parts of the device. Make sure that no water can
penetrate the device interior. Water penetrating
an electric device increases the risk of an electric
shock.
14. Storage
Store the device and its accessories in a dark, dry and
frost-free place that is inaccessible to children. The
optimum storage temperature is between 5 and 30˚C.
Store the electric tool in its original packaging.
Cover the electric tool to protect it from dust or mois-
ture.
Store the operating manual with the electric tool.
15. Maintenance
Attention!
Disconnect the mains plug before carrying out any
maintenance work.
General maintenance tasks
Wipe swarf and dust off the machine from time to time
with a cloth.
Do not oil the motor.
Do not use corrosive cleaning agents for cleaning the
plastic.
12. Electrical connection
The electrical motor installed is connected and ready
for operation. The connection complies with the appli-
cable VDE and DIN provisions.
The customer‘s mains connection as well as the ex-
tension cable used must also comply with these reg
-
ulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly.
Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap
-
plicable VDE and DIN provisions.
Only use connection
cables with the designation H05VV-F.
The printing of the type designation on the connection
cable is mandatory.
Connection type Y
If the power cord of this device is damaged, it must be
replaced by the manufacturer, their service department
or a similarly qualified person to avoid dangers.
AC motor
• The mains voltage must be 220-240 V~.
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm2.
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Содержание 5901511901
Страница 2: ...www scheppach com 2 1 5 1 2 3 4 6 7 8 ...
Страница 3: ...www scheppach com 3 2 3 4 9 10 11 12 15a 15 16 17 13 14 ...
Страница 4: ...www scheppach com 4 5 18 19 20 21a 21 22 6 23 24 25 22 19 26 24 A B C 15 15a 16 7 ...
Страница 243: ...www scheppach com 243 ...
Страница 244: ...www scheppach com 244 ...
Страница 248: ...www scheppach com 248 ...
Страница 252: ...www scheppach com 252 ...