Operating and Installation Overvoltage Protection OVP 01 A
6
Issued: 20.12.2011
822.221 BA / EN
1.6
Maintenance
The overvoltage protection does not require maintenance.
1.7 Technical details
1.7.1 Mechanical data
130 x 47 x 90 (H x W x D in mm), without an inlet connector for non-heating
appliances
196 g
Plastic blue, (RAL 5010)
1.7.2 Electrical data
230 V, 47 -- 63 Hz, sinusoidal, protection class 1
Overvoltage: approx. 265 V
∼
eff.
Low voltage: approx. 175 V
∼
eff.
These values apply for an undistorted sinus voltage.
for overvoltage: low than 10 ms
greater than 1 s
2000 W max.
1.7.3 Environmental parameters
-10
°
C to +45
°
C
-20
°
C to +70
°
C
Operation in dry environment only
CE mark
Dimensions
Weight
Casing
Operating voltage
Breaking voltage
Switch off delay
Switch off time
Connection load
Operational temperature
Storage temperature
Humidity
CE