CamperEnCaravanOnderdelen.nl
Instruction Manual for the LT 4XX Family of Switch Panels
10
Date: 13.09.2013
831.414 BA / EN
3.6.3.3
Additional devices
*Only LT 400, 402:
"
Press the switch with the symbol for additional device(s) (Aux,
) up-
wards.
The supply voltage for the additional device(s) is switched on:
F
Green LED lights up.
F
Connected device(s) can be switched on.
3.7
Troubleshooting and remedies
3.7.1
Alarms
Y
ATTENTION!
Total discharge.
Damage to the living area battery:
F
Prevent low battery charge (indicated by low voltage).
F
Check the voltage regularly (see Section 3.6.1).
Y
Carry out checks in the mornings before 12V consumers are switched
on.
Alarm
Possible cause
Remedy
Risk of draining the living
area battery.
Switch off all 12V
consumers.
y
Voltage of the living area
battery has fallen below
11.0V.
Recharge the battery:
-- Start engine
or
-- connect to 230V power
supply
3.7.2
Faults
The majority of power supply system faults are caused by blown fuses (refer
to the instruction manual for the relevant electrobloc for information on vol-
tage distribution and fusing).
Please contact our customer service department if you can not rectify the
fault using the following table.
If this is not possible, e.g. if you are abroad, the switch panel can be repai-
red at a specialist workshop. Please note that the warranty will become void
if incorrect repair work is carried out. Schaudt GmbH shall not accept liability
for any damages resulting from such repairs.
Fault
Possible cause
Remedy
12V supply does not
function (or some areas
t
d)
12V main switch is
switched off.
12V main switch must be
switched on.
(
are not powered).
Fuse blown.
See EBL ... electrobloc
instruction manual. .
Flat vehicle fuses