Installation instructions for solar charge regulator LR 1218
8
Date: 22.09.2009
822.212 MA / EN
Disconnect in reverse order.
5.3 Connection to an EBL ... electrobloc with 3-pin MNL con-
nection and adapter for starter battery
When using an electrobloc which only has a 3-pin connection for a solar
charge regulator, an adapter for charging the starter battery can be retrofit-
ted. It is then possible to charge the living area battery and the starter bat-
tery simultaneously.
The following electroblocs (as of April 2008) can be used with the adapter:
F
EBL 99
F
EBL 100
F
EBL 264-9
F
EBL 240
F
EBL 269
An IT 300 Solar display panel, for the display of the solar charge current,
can be used as an optional extra.
For this application, the follow parts are required from those delivered:
Pos.
Qty
Name
1
1
LR 1218 solar charge regulator
2/3
1
20A or 15A flat vehicle fuse (depending on EBL ...)
3
1
Flat vehicle fuses
8
2
Flat push-on contacts, 6.3 x 0.8 (blue)
9
1
EBL ... connector cable (caravan battery charge current)
10
1
EBL ... adapter cable (starter battery charge current)
G3
+
--
--
+
LR 1218
Ya
X3
Y1
black
blue
X
*
*
Yb
black
brown
yellow
brown
red
red
X1
Fig. 4
Circuit diagram of connection LR 1218 to EBL ...
Disconnection