811.598 BA / EN
Situation: 25.06.2010
3
Instruction Manual Electrobloc EBL 269
▲
Blown fuses must only be replaced when the cause of the fault is
known and eliminated.
▲
Never bridge or repair fuses.
▲
Danger of burning! Blown fuses must only be changed on a zero-cur-
rent Electrobloc.
▲
Only use original fuses rated as specified in the instruction manual.
▲
Danger of burning! During operation the back of the Electrobloc gets
hot. Do not touch.
▲
Danger of explosion from formation of detonating gas due to an incor-
rectly set battery selector switch, defective batteries, defective Elec-
trobloc or an excessively high battery working temperature (more than
30 °C).
▲
The mains connection line may only be replaced by an authorised cus-
tomer service department or by qualified persons.
▲
The AES refrigerator fuse may only be used if a AES refrigerator is con-
nected. Otherwise, the living area battery may get totally discharged. Bat-
tery damage is possible.
▲
An incorrectly set battery selector switch damages the living area battery.
▲
Disconnect the Electrobloc from the mains before adjusting the battery
selector switch.
▲
If the living area battery is changed or removed, the frost protection valve
on the heater system opens automatically. Water may be lost. For more
information, see the instruction manual of the heater system.
▲
Before and after shutdown, the living area battery must be fully recharged
to avoid battery damage. For this purpose the vehicle must be connected
to mains supply for a minimum of 12 hours with an 80 Ah battery and
24 hours with a 160 Ah battery.
▲
Do not operate the Schaudt solar charge regulator without a battery. This
might damage the solar charge regulator or any connected consumers. If
the battery is going to be changed or removed, take off the positive lead
"+ Solarzelle" (+ Solar Module) on the solar charge regulator.
▲
To avoid voltage peaks during warm-up, do not connect the generator until
it is running in a stable manner. Otherwise, the Electrobloc, the 12 V con-
sumers or other connected equipment might get damaged. It is essential
that the generator complies with the mains supply specifications.
▲
The mains supply on board car ferries might not always be perfect. There-
fore, never connect the Electrobloc to the mains on car ferries. Otherwise,
the Electrobloc, the 12 V consumers or other connected equipment might
get damaged.