Instruction Manual Electrobloc EBL 208 S G
R
6 Operation
6.1 Operating controls
Flat vehicle fuses
The flat vehicle fuses protect the various circuits. When necessary, take off
the blue cover marked "FUSE" (optional) and check or change the fuses.
Battery cut-off switch
The battery cut-off switch "Battery on/off" disconnects the following connec-
tions from the living area battery:
●
all 12 V consumers except the AES refrigerator and the entrance step
●
the frost protection valve
●
the control and switch panel
This prevents the living area battery from slowly discharging due to closed cir-
cuit current while the vehicle is not in use.
The batteries can still be charged using the Electrobloc, the alternator or the
solar charge regulator, even when the battery cut-off switch is switched off.
❱
To start the system, set the battery cut-off switch to "Battery on".
❱
To shut down the system, set the battery cut-off switch to "Battery off".
Starter battery
Charging current
Float charge of starter battery at
max. 2 A
Battery charging via solar
charge regulator
Only the living area battery is charged.
Maximum charging current
14 A, fuse-protected by 15 A fuse
Battery charging while
travelling
Simultaneous charging of the starter battery and the living area battery by the
alternator
Batteries connected in parallel via a cut-off relay
Battery monitor
Breaking voltage
Approx. 10.5 V
Minimum battery voltage for
switching on via 12 V main
switch on the control panel
Approx. 11.0 V
▲
Blown fuses must only be replaced when the cause of the fault is
known and eliminated.
▲
Never bridge or repair fuses.
▲
Danger of burning! Blown fuses must only be changed on a zero-cur-
rent Electrobloc.
▲
Only use original fuses rated as specified in the instruction manual.
▲
The AES refrigerator fuse may only be used if a AES refrigerator is con-
nected. Otherwise, the living area battery may get totally discharged. Bat-
tery damage is possible.