background image

DT 220 B control and switch panel instruction manual

12

Issued: 30.06.2006

830.588 BA / EN

³

Use the “+” or “--” buttons to set the year.

³

Confirm the entry by pressing “OK”.

³

Press the “Set up” menu button.

F

The day display flashes.

³

Use the “+” or “--” buttons to set the day.

³

Confirm the entry by pressing “OK”.

F

The month display flashes.

³

Use the same procedure to set the month.

³

Press the “Main menu” button when you have completed all of the

entries.

F

The display will remain illuminated.

F

The main menu is now displayed.

5.4.2.2 Set up the installed (nominal) battery capacity for the lei-

sure battery

³

Press the “Battery menu” button.

F

The display will illuminate.

F

The remaining utilisable leisure battery capacity will now be displayed.

³

Press the “Set up” menu button and keep it held down for at least 3 s.

F

The display will change over to battery menu set up mode.

F

The maximum utilisable leisure battery capacity will now be displayed.

The system uses the “installed (nominal) battery capacity” to calculate

this value.

³

Now press the “Set up” menu button once again as long as the display is

lit up.

F

The installed (nominal) leisure battery capacity display will flash.

Содержание DT 220 B

Страница 1: ... Table of contents 1 Introduction 2 2 Safety information 2 2 1 Significance of the warning signs 2 2 2 General safety instructions 2 3 Application and function 3 4 Design 5 5 Operation 5 5 1 Operating controls 5 5 2 Display controls 6 5 3 Reactivation following shutdown 9 5 4 Switching on 10 5 5 Display menus 15 5 6 Troubleshooting and remedies 21 5 7 Switching off 25 5 8 Closing down the system 2...

Страница 2: ...f the art and complies with the approved safety technology Nevertheless somebody might be injured or the device might be damaged if you do not abide by the safety information given in this instruction manual Do not use the device if it is not in a perfect technical condition Any technical faults affecting the personal safety or the device must be dealt with immediately by qualified personnel Y DAN...

Страница 3: ...ce 3 Application and function The DT 220 B control and switch panel is the central operating unit for the EBL Electrobloc which supplies all of the 12 V electrical supply s consu mers onboard the motorhome or caravan It is usually installed in an easily accessible spot that is high up near the door of the motorhome or caravan EBL Control and Electrobloc 230 V AC 12 V consumer Living area battery S...

Страница 4: ...her option F Waste water tank F Extra tank optional can be installed as a water tank waste water tank or sewage tank F Truma Triomatict or Truma Duomatic L Plust F Internal or external temperature sensors The DT 220 B control and switch panel is responsible for controlling the electrical functions in the motorhome s living area and displaying various measured values The following data can be displ...

Страница 5: ... 8 Menu buttons 5 Operation 5 1 Operating controls The DT 220 B control and switch panel has the following controls fitted to it Main switch Button for switching the 12 V supply in the motorhome or caravan on or off Menu button Main menu Menu button Battery menu Menu button Tank menu Menu button Set up or button context sensitive For paging through the menus or altering the displayed setting A or ...

Страница 6: ...y and temperature display The symbols mean the following Symbol Meaning Symbol Meaning Leisure battery An alarm is on Starter battery Solar charging Internal tempera ture Water pump External tempera ture Acoustic warning Water tank example shows 50 filling level Reserve gas cylin der Waste water tank example shows 25 filling level EisEx Water tank 2 example shows 0 filling level Tank heating Sewag...

Страница 7: ...3 s Fig 4 Main menu menu structure This window is only displayed when the Truma Duomatic L Plus or Truma Triomatic option is fitted and is active see installation instructions Contents are shown as examples only Y How to operate the main menu is described in Chapter 5 5 1 Main menu and settings in main menu ...

Страница 8: ...nd buttons press OKn to confirm Service menu for manufacturer only Or else return to the main or tank menus the starter battery for the 24 V design is not charged by solar energy Only displayed when the Read solar current option is active Sample display for 24 V main battery Y How to operate the battery menu is described in Chapter 5 5 2 Battery menu and settings in battery menu ...

Страница 9: ...s assumes that the 12 V system was closed down the last time you left the vehicle battery isolation activated see Chapter 5 8 Therefore the dis play is not switched on Press the 12 V button and keep it held down for longer than 5 s F The display will illuminate F The motorhome and leisure battery symbols flash F After 5 s Battery isolation will be deactivated The system is now switched on Set the ...

Страница 10: ...wing loads are also operational when the 12V power supply is swit ched off F Frost protection valve F Heater F Step F Gas alarm waste water valve F Power circuit 4 F Waste water tank heating F Fold away bed F Awning light F Awning F Aerial F AES compressor refrigerator F Fridge controller These consumers are always at stand by even with the 12 V power supply switched off Y To start these consumers...

Страница 11: ...tting up Y The settings are entered via the setting up modes in the various menus Setting up mode is called up using the Set up button You can exit setting up mode from any point just by pressing one of the Main menu Battery menu or Tank menu buttons Pressing the 12 V main switch will also exit setting up mode Any entries that have not been saved press the OK button to save them will be lost 5 4 2...

Страница 12: ...main menu is now displayed 5 4 2 2 Set up the installed nominal battery capacity for the lei sure battery Press the Battery menu button F The display will illuminate F The remaining utilisable leisure battery capacity will now be displayed Press the Set up menu button and keep it held down for at least 3 s F The display will change over to battery menu set up mode F The maximum utilisable leisure ...

Страница 13: ...be displayed but not adjusted you must not press the OK button To leave the menu press one of the menu buttons the menu is automatically switched off after 20 se conds Press the OK button if the display is lit up Press the Battery menu button when you have completed all of the entries F The display will remain illuminated F The remaining utilisable leisure battery capacity will now be displayed Th...

Страница 14: ...he control and switch panel DT 220 B is in this mode the OK button is used to switch the current setting 5 4 2 5 Switching the tank alarm on and off Y The tank alarm can for instance be switched off when the water tank is constantly empty e g city water connection The tank alarm can only be switch on or switched off for all tanks at once Press the Tank menu button F The display will illuminate F T...

Страница 15: ...Confirm the entry with the OK button If necessary continue program ming When you have made all entries press the menu button Main menu F The display is lit up F The main menu is displayed 5 5 Display menus 5 5 1 Main menu Y The main menu showing time will be displayed automatically every 20 s after the last button was pressed Press the Main menu button F The display will illuminate F The time and ...

Страница 16: ...evant fittings solar control and solar cells are connected up to the EBL Electrobloc and the Read solar current option is active Only the vehicle manufactu rer can activate it at a later date The button can also be used to move forward to the next page Use the button to return to the previous page Y The OK button can be used in the utilisable leisure battery capacity page to move between the absol...

Страница 17: ...ur for lead acid battery F 8 hours for lead gel battery 1 Depending on the current load Measuring the off load voltage is an additional way of assessing the condi tion of the battery Off load voltage is the voltage of the charged battery in a passive state with no current being supplied or drawn Take the measurement several hours after the last charging In the mean time no significant load should ...

Страница 18: ...ove 80 Polling Switching the system on see Chapter 5 4 1 Press the Battery menu button Press the Set up menu button and keep it held down for at least 3 s F The display will change over to battery menu set up mode F The leisure battery symbol is now displayed The associated maxi mum value is also displayed The full or flat battery status is detected by the control and switch panel The maximum capa...

Страница 19: ... F Variable nominal capacity setting e g if a battery with a greater capacity is retrofitted Y The battery should be recharged at regular intervals Otherwise a request will be issued Charge and Date see Chapter 5 6 1 as well 5 5 2 4 Solar current Y The solar current display is only available if a Schaudt GmbH LRS solar charger is fitted and the Read solar current option is active Solar charging cu...

Страница 20: ...k 2 or sewage tank exists and Extra tank 2 waste water Extra tank 2 sewage or Extra tank 2 water is active Only the vehicle manufacturer can activate it at a later date The button can also be used to move forward to the next page Use the button to return to the previous page The tank monitor automatically checks the water and waste water filling levels once a minute or when changing to the tank me...

Страница 21: ... Damages the leisure battery F Prevent a low battery charge which is indicated by low voltage F Check the battery capacity regularly see Chapter 5 5 2 3 for best method F Check the voltage regularly see Chapter 5 5 2 2 for alternatives Alarm Possible cause Remedy CHARGE alarm is also displayed when 12 V supply is switched off Battery voltage is too low The system shuts down automatically after app...

Страница 22: ...e stopped Water tank sensor fault Clean the sensors and check as necessary Main menu 230 V power supply has failed or else it has been di t d f th 230 V supply must be con nected up or switched on disconnected from the motorhome Starting the engine motorhome Acknowledge the alarm if you have deliberately dis connected it switched off Press Main menu button Press OK button F The symbol will disap p...

Страница 23: ...symbol will disappear Inform customer service dealer The acoustic warning signal must be switched off after every engine start until the malfunction has been rectified Only applicable if Truma Duomatic L Plus is fitted Main menu One of the gas cylinders is empty Replace the empty gas cylinder with a full one Main menu Both gas cylinders are empty Replace the empty gas cylinders with full ones If t...

Страница 24: ...eisure battery Fuse blown See EBL Electrobloc instruction manual Leisure battery is flat Leisure battery has been discharged Recharge the leisure battery immediately The leisure battery will be irreparably damaged if it remains totally discharged for a lengthy period The battery can be discharged by inactive consumers such as the frost protection valve in the combined heating system Fully recharge...

Страница 25: ...ou are not go ing to use the motorhome for a lengthy period i e during the winter The system is equipped with a battery isolator that completely isolates the leisure battery electrically from the vehicle Press the 12 V button briefly F The display will illuminate Press the 12 V button briefly once again F The system has now been switched off F 12 V OFF is displayed on the screen Press the Battery ...

Страница 26: ...EBL Electrobloc instruc tion manual 6 Maintenance The control and switch panel requires no maintenance Clean the front plate using a soft moist cloth and mild detergent Never use spirit thinners or similar substances Do not allow fluid to ingress the control and switch panel Clean the sensors probes the sensor probe surfaces must always be clean Inform Schaudt GmbH customer service department if a...

Страница 27: ...ny B Special fittings Accessories Per tank 1 x tank probe rod 1 x seal 1 x locking nut 1 x probe cable 5 x 0 5 optional extras Alternative per tank 1 x capacitance tank probe for infinitely variable display of the level in the water tank Alternative per tank 5 x tank sensor 1 x sensor cable 5 x 0 5 It is also possible to operate tank probes and tank sensors together C Customer service Schaudt GmbH...

Страница 28: ...he addressee delivered free The switch panel must be transported in the ESD protective bag as supplied by us There are components fitted on the control and switch panel PCB that can be destroyed by an electrostatic discharge ESD Do not touch the components fitted on the PCB A suitable bag can be ordered from Schaudt GmbH if you do not have one available ...

Страница 29: ...____________ SW vers _______________________ see Chapter 5 6 3 Vehicle Manufacturer _______________________ Model _______________________ Own installation Yes No Upgrade Yes No There is the following defect please tick Other remarks No battery charging whilst driving No battery charging from mains Tank Voltage Current Permanent fault Temporary fault loose contact The following electrical consumers...

Страница 30: ... 4 Main switch relay 2 On 5 Mains signal 6 Sh t id X7 ELCO 8263 3 way 1 Minus 2 EisEx 3 Gas Reserve 1 5 Mains signal 6 Shunt consumer side 7 Shunt battery side 8 Leisure battery negative sensor 9 Lighting negative 10 Leisure battery sensor 11 Starter battery 12 V 12 Lighting X8 ELCO 8263 3 way 1 Minus 2 EisEx 3 Gas Reserve 2 X3 Lumberg MSFQ 6 way 1 Full 2 3 4 3 1 2 4 1 4 5 Fresh water tank base 6 ...

Отзывы: