SDT-0018-02EN
Situation: 18.07.2005
19
Instruction Manual Control and Switch Panel DT 201 B
5.7.9
Gas alarm
For additional equipment Truma Duomatic L plus: If one of the two gas cylin-
ders is empty, the spare cylinder symbol appears in the basic display. As soon
as the second gas cylinder is empty, the spare cylinder symbol and the
"ALARM" message appear.
5.7.10
Tank sensor fault message
If there is a malfunction of the water or waste water sensors, a "?" flashes in
the tank display.
Clean the tank sensors of the respective tank.
If the fault message is still displayed after cleaning, customer service must be
informed.
5.7.11
Temperature fault message
If there is a malfunction of the temperature sensors or if a temperature is not
within the range of between -40 °C and +60 °C, a "?" is indicated in the tem-
perature display.
5.7.12
Date message
DATE
If no date has been entered in the basic menu, the word "DATE" flashes. The
date display is required for the capacity display to work properly.
6
Starting up
The control and switch panel DT 201 B can only be started up with the Elec-
trobloc EBL 101 and the accessories for measuring the water tank levels.
Starting up the system
Set the battery cut-off switch on the Electrobloc to "Batterie Ein" (battery
on). Follow the instruction manual of the Electrobloc.
Press the 12 V main switch on the control and switch panel.
After shutting down
If the battery is disconnected from the system (battery cut-off switch is turned
off on the Electrobloc or a battery pole is disconnected): Check the off-load
voltage of the battery immediately after start up. Do not connect the vehicle
to the 230 V mains, do not start the engine and do not switch on any consum-
ers until the off-load voltage of the battery has been checked.
After an off-load time of maximum 6 months, the battery voltage should be
above 12.7 V if the battery was fully charged before shut down. If voltage is
below 12.0 V then the battery might be defective and need to be replaced.
W
After switching on the battery cut-off switch or after changing batteries:
Switch on the 12 V main switch on the control and switch panel briefly to
start up the consumers.
W
Connection work is to be carried out in tensionless condition only.