background image

1. Important Safety Information

1.1 Intended Use

The Schartec Porte 

30

0 swing gate opener is intended exclusively for the operation of 

smooth-running

 

swinging gates in private, non-commercial areas. The maximum permissible gate size and maximum weight 

must not be exceeded. The 

gate

 must be easy to open and close by hand. Regional wind loads must be 

taken into account when using 

gate

 fillings

/panels

 (EN 13241-1). Observe the manufacturer's instructions 

regarding the combination of 

gate

 and operator. Possible hazards in regards to DIN EN 13241-1 will be 

avoided when the installation and assembly is completed according to our specifications. Gate systems 

which are located in the public area and are protected by only one protective device, e.g. force limitation, 

may only be operated under supervision.

1.2 Unintended use

Continuous operation and use in the commercial sector is not permitted. The 

operator

 is not designed for the 

use

 of heavy-duty gates

 or gates that are larger than the specified permissible size and weight

. Use on gates 

with inclines or slopes is not permitted.

1.3 Qualifi

c

ation 

of the fitter/installer

Safe and intended functioning of the mounting and installation can only be ensured when the correct 

installation and maintenance is carried out by a competent / knowledgeable company or a competent / 

knowledgeable person in accordance with the instructions. A qualified person is, in accordance with EN 

12635, a person with appropriate training, knowledge, and experience to correctly safely assemble, test, and 

maintain a 

gate

 system.

1.4  

Safety instructions for installation, maintenance, repair, and dismantling of the gate system

 

WARN

I

NG! 

Risk of injury due to unexpected gate travel.

The installation, maintenance, repair, and dismantling of the gate system and the gate operator must be 

carried out by qualified persons. In the event of failure of the gate system and the gate operator, immediately 

commission a qualified person for inspection and/or repair.

1.5 

Safety instructions for installation

The qualified person must ensure that the current work safety regulations and the regulations governing the 

operation of electrical equipment are followed when performing the installation work. In doing so, the national 

guidelines must be observed. Potential hazards in regards to DIN EN 13241-1 are avoided when the 

construction and assembly according to our specifications are followed. After completion of the installation, 

the installer of the system must be able to declare conformity to DIN EN 13241-1 in accordance with the 

scope of application.

1.6

 

Safety instructions for commissioning and operation

Danger of injury due to damaged components.

Faults with the gate system or incorrectly aligned gate doors can lead to serious injuries! Do not use the gate 

system if repairs or adjustments have to be made! Check the entire gate system (hinges, gate bearings, 

springs, and mounting hardware for wear and possible damage. Check for rust, corrosion, and cracks.) For 

your own safety, have maintenance and repair work carried out by a qualified person only!

For your own safety, have any required maintenance and repair work to the gate done by a qualified person 

before you install the gate operator. Only correct installation and maintenance by a competent company or 

competent person in accordance with the instructions can ensure the safe and intended functioning. The 

qualified person must ensure that the applicable regulations regarding occupational safety and those 

governing the operation of electrical devices to be followed when carrying out the installation work. Here, the 

national guidelines must be observed. Possible hazards are avoided when the construction and assembly 

according to our specifications is carried out. Prior to installation, disable the gates mechanical interlocks, 

which are not required for operation with the door operator, or disassemble them completely if necessary. 

These include in particular the locking mechanisms of the gate lock. Check that the gate is mechanically 

faultless so that it can be easily 

operated manually

 and can be opened and closed properly (EN 12604).

3

Содержание Porte 300

Страница 1: ...Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only Signal Light Control Box Push button Gate 2 Gate 1...

Страница 2: ...3 4 Remote Controls Hand transmitters 2 3 5 Signal Light 2 3 6 Key Switch 2 3 7 Push Button 2 3 8 Electric Lock and Stopper Plate 3 Installation 3 1 Notes on use of the operator 3 1 1 Tools needed for...

Страница 3: ...and or repair 1 5Safety instructions for installation The qualified person must ensure that the current work safety regulations and the regulations governing the operation of electrical equipment are...

Страница 4: ...dren should be supervised to ensure that they do not play with the device 11 Electrical items do not belong in the household waste but must be disposed of properly Check with your local authorities ci...

Страница 5: ...ignal light H Control box I Electric lock J Stopper plate K Screws bolts and nuts Figure 2 2 Product description and application F G H I J K Figure 1 2 1 Application This gate operator is suitable for...

Страница 6: ...iver and a transformer With the help of the control all functions of the swing gate operator are configurable Furthermore there are terminals on the motherboard for connecting various accessories 2 3...

Страница 7: ...key switch is used to operate the swing gate operator with the turn of a key It s surface mounted and two keys are included in the delivery 2 3 7 Push button The interior push button is used to opera...

Страница 8: ...box is via a 3 wire cable Carefully read the assembly instructions for the gate operator before proceeding Make sure that the cables are properly layed and and properly inserted to prevent cable break...

Страница 9: ...ves Porte 300 Porte 300 1 Make sure that the gate weight and gate width do not exceed the specified maximum values of the operator 2 Make sure that the gate construction is designed for the forces of...

Страница 10: ...le of the gate leaf Example If A is 160 mm and the opening angle is 100 then the distance B should be about 190 mm Please make sure that the dimensions B and A on both sides are approximately equal or...

Страница 11: ...e rear plate of the bracket at the intended mounting point Check the distances as shown in Figure 23 8 If the bracket is at the point where it should be mounted then mark the four holes Use an 8 mm dr...

Страница 12: ...the screw for the bolt See Figure 27 14 Tighten the bolt with the nut on the rear bracket then loosen the nut half a turn to allow the motor arm to rotate 15 Now tighten the screw with the nut on the...

Страница 13: ...Max Working Current Max Gate Weight Max Gate Width Operating Temperature Dimensions Weight 24 V DC with mechanical unlocking release Worm Gear 3000 N 350 mm 24 V DC 4 A for max 10 seconds 300 kg per...