Operation Manual VISATRON® VN115/87plus EX
06/2016
Page 17
SCHALLER AUTOMATION
D-66440 Blieskastel / Saarland / Germany / Industriering 14 / P.O Box 1280
Industrielle Automationstechnik GmbH & Co. KG
Tel. +49(0)6842-508
-
0
/ Fax -260 / eMail: [email protected] / www.schaller.de
2.1.3
Installation of pipe siphons
Figure 7:
Pipe siphon
Mount the engine wall connection into the G3/4" thread with 110 Nm torque
Put the pipe siphon in the hole
Fix the clamping nut
Fill the pipe siphon with oil (see chapter 'commissioning')
Fix the flexible tube on the top fitting