background image

Operating and mounting instructions according to ATEX for 

RS-N/RS-M/MWK-OB/MWS-OB/MWK-MB/MWS-MB

Z10/03 - 3

Construction subject to change.

No return possible!

06.02.2018

Version:

General conditions

General description and instructions

These additional operating instructions must be observed prior

to mounting and commissioning the device.

These additional operating instructions contain basic informa-

tion regarding its use in areas subject to explosion hazards to be

observed during assembly, operation and maintenance.

Prior to mounting and commissioning and during maintenance

work, the present additional operating instructions must be read

by the installer and the responsible skilled personnel/system

operator!

Personnel qualification and training

The personnel for assembly, inspection and maintenance must

have the relevant qualification for this work.

The area of responsibility, competence and monitoring of the

personnel must be exactly regulated by the system operator. If

the personnel does not have the required knowledge, it must be

trained and instructed. Moreover, the system operator must en-

sure that the contents of the additional operating instructions

are understood completely by the personnel.

Safety-conscious work

The safety instructions given in these additional operating in-

structions, the existing national and international regulations on

explosion protection, accident prevention and the system oper-

ator's internal work, operating and safety regulations must be

observed.

Designated use

The devices have been designed for use in ventilation systems

in areas subject to explosion hazards according to ATEX of Cat-

egory II, Zones 1, 2 and Category III, Zones 21, 22.

These devices are not suitable for use in unreleased Ex zones.

The operating safety of the delivered devices is only guaranteed

when used in accordance with their designated use.

Delivery and storage

Upon receipt, the devices must be checked for completeness

and transport damage. If delivered incompletely or damaged,

the forwarding company and the SCHAKO KG have to be in-

formed immediately.

The device must not be exposed directly to weather, solar radi-

ation and moisture.

Mounting information

Mounting, electrical connection work and commissioning must

be carried out by skilled personnel only and in accordance with

the recognised technical rules and the safety and accident pre-

vention regulations. 

Maintenance

Only a device subjected to proper maintenance and kept in per-

fect condition can guarantee safe and reliable operation.

When defective parts are replaced with spare parts, only SCHA-

KO original spare parts may be used. The SCHAKO KG cannot

be held liable for any damage caused by using spare parts that

are not original and will not give any warranty.

Hazard caused by non-observance of the safety in-

structions

Non-observance of the safety instructions can result both in

putting persons and the environment and operating units at risk.

Likewise, non-observance of the safety instructions will result in

the loss of any claims for damages.

Содержание MWK-MB

Страница 1: ...Steigstraße 25 27 D 78600 Kolbingen Telephone 49 0 74 63 980 0 Fax 49 0 74 63 980 200 info schako de www schako de Additional operating instructions according to ATEX 94 9 EC Silencer RS N RS M MWK OB MWS OB MWK MB MWS MB ...

Страница 2: ...ption and instructions 3 Personnel qualification and training 3 Safety conscious work 3 Designated use 3 Delivery and storage 3 Mounting information 3 Maintenance 3 Hazard caused by non observance of the safety instructions 3 Models and dimensions 5 Dimensions 5 Dimensions of accessories 7 Information regarding assembly and commissioning 8 Information regarding maintenance and inspection 8 Certifi...

Страница 3: ...m oper ator s internal work operating and safety regulations must be observed Designated use The devices have been designed for use in ventilation systems in areas subject to explosion hazards according to ATEX of Cat egory II Zones 1 2 and Category III Zones 21 22 These devices are not suitable for use in unreleased Ex zones The operating safety of the delivered devices is only guaranteed when us...

Страница 4: ...ion openings in sufficient number and size must be provided on site Installation of baffles or silencers When baffles are delivered separately the determined perform ance data are only reached if the manufacturer s installation in structions and the recognised technical rules are observed The mineral wool silencer should be laid out inside the ventilation in stallation in front of the air filter s...

Страница 5: ...98 400 500 600 315 313 415 515 615 350 348 450 550 650 355 353 455 555 655 400 398 500 600 700 450 448 650 750 500 498 700 800 560 558 760 860 600 598 800 900 630 628 830 930 710 708 910 1010 Selection chart packing thickness NW L 500 L 950 L 1450 L 1950 P mm P mm P mm P mm 50 100 150 50 100 150 50 100 150 50 100 150 71 x x x x x x 80 x x x x x x 90 x x x x x x 100 x x x x x x 112 x x x x x x 125 ...

Страница 6: ... sizes NW ød øD T mm P mm 50 100 150 350 348 450 550 650 60 355 353 455 555 655 60 400 398 500 600 700 60 450 448 550 650 750 60 500 498 600 700 800 75 560 558 760 860 100 600 598 800 900 100 630 628 830 930 100 710 708 910 1010 150 Selection chart packing thickness NW L 950 L 1450 L 1950 P mm P mm P mm 50 100 150 50 100 150 50 100 150 350 x x x x x x x 355 x x x x x x x 400 x x x x x x x 450 x x ...

Страница 7: ... data on request The model D300 is assembled with mineral fibre boards 100 200 mm Detail X at D 100 200 and H2 200 at D 300 and or at H2 200 round design rectangular design Dimensions of accessories Additional angled frame at an extra charge Detail Y L1 L2 H1 H2 D 100 S 40 100 B1 mm D 200 S 50 200 B1 mm n mm mm 500 750 1000 1250 1500 1750 2000 2250 2500 3000 250 140 200 250 400 1 500 280 400 500 8...

Страница 8: ...malous operating conditions such as vibrations pressure surges or high proportions of solids in the medium Information regarding maintenance and inspection Proper maintenance increases operational safety and the serv ice life of the device This is why the devices should be subjected to regular inspection If inspection dates are prescribed by law they must be complied with The operating personnel m...

Страница 9: ...Operating and mounting instructions according to ATEX for RS N RS M MWK OB MWS OB MWK MB MWS MB Z10 03 9 Construction subject to change No return possible 06 02 2018 Version Certificate of conformity ...

Страница 10: ...Operating and mounting instructions according to ATEX for RS N RS M MWK OB MWS OB MWK MB MWS MB Z10 03 10 Construction subject to change No return possible 06 02 2018 Version ...

Страница 11: ...Operating and mounting instructions according to ATEX for RS N RS M MWK OB MWS OB MWK MB MWS MB Z10 03 11 Construction subject to change No return possible 06 02 2018 Version ...

Страница 12: ...Operating and mounting instructions according to ATEX for RS N RS M MWK OB MWS OB MWK MB MWS MB Z10 03 12 Construction subject to change No return possible 06 02 2018 Version ...

Отзывы: