Standard GigE Network Adapters
•
For non-Intel PRO/1000 network adapters
install the driver recommended by the
manufacturer.
!
This kind of GigE network adapters do
require additional setup. These settings
should be optimized during installation in
the Advanced Properties tab
D
of the
Network Adapter:
Jumbo frames = 9014 Bytes
Receive Descriptors (Empfangsdescriptors) = 2048
Interrupt Moderation Rate (Interrupt-Drosselungsrate) = extreme
LAN adapters that do not work with the High Performance Driver must use a fixed IP address, e.g.
G cameras: 192.168.0.99, V cameras: 169.254.0.99
D
SkLineScan Start-up
•
Start SkLineScan. A start-up dialog box pops up and displays the
connected cameras that have been automatically detected.
Initial Function Test
•
Quit the SkLineScan startup dialog box.
•
Select "OK" in the SkLineScan start-up
dialog.
The oscilloscope display showing the current
brightness versus the pixel number indicates
the correct installation.
Camera Setup
Use the Setup dialog for
• activating/deactivating a
connected GigE camera
(activated device is
ticked)
•
changing the IP address
•
changing the pixel
frequency
•
setting the bit depth of
the video signal to 8, 10, or 12-bit.
The MAC addresses are displayed for identification of each camera with the defined CamID (0, 1, …). This is
useful when several cameras with the same name are connected.