f means PID control is functional in
the area of set temperature±Diff, the
unit is 0.1ºC, the defaulted value is
100; if the temperature is less than
set
temperature–Diff
(
positive
action
),
PID
output
is
the
maximum value; if the temperature
is more than set tempDiff,
the PID output is the minimum
value.
4x139
Channel 1 PID parameter I
4x140
Channel 1 PID parameter D
4x141
Channel 1 PID parameter Diff
4x142
Channel 2 PID parameter P
4x143
Channel 2 PID parameter I
4x144
Channel 2 PID parameter D
4x145
Channel 2 PID parameter Diff
4x146
Channel 3 PID parameter P
4x147
Channel 3 PID parameter I
4x148
Channel 3 PID parameter D
4x149
Channel 3 PID parameter Diff
4x150
Channel 4 PID parameter P
4x151
Channel 4 PID parameter I
4x152
Channel 4 PID parameter D
4x153
Channel 4 PID parameter Diff
4x154
Channel 5 PID parameter P
4x155
Channel 5 PID parameter I
4x156
Channel 5 PID parameter D
4x157
Channel 5 PID parameter Diff
4x158
Channel 0 Temperature control period
Control period adjust range is
0.5~200s, minimum precision is
0.1s. The unit is 0.1s, it means you
need to write 5 while the actual
period is 0.5s.
4x159
Channel 1 Temperature control period
4x160
Channel 2 Temperature control period
4x161
Channel 3 Temperature control period
4x162
Channel 4 Temperature control period
4x163
Channel 5 Temperature control period
4x164
Channel 0 Actual temperature
Actual temperature: the users can
set the actual temperature when
they found the actual temperature is
different
from
the
displayed
temperature, the unit is 0.1ºC ( the
write method is the same as "the set
temperature" ). When the module is
written into this value, temperature
difference
value
δ
=
actual
temperature – sampling temperature.
4x165
Channel 1 Actual temperature
4x166
Channel 2 Actual temperature
4x167
Channel 3 Actual temperature
4x168
Channel 4 Actual temperature
4x169
Channel 5 Actual temperature
4x170
Channel 0 Self-study output range
Self-study output range: the output
quantity of self-study, the unit is %,
100 means the mark-space ratio is
100% of the full-scale output, 80
means 80% of the full-scale output.
4x171
Channel 1 Self-study output range
4x172
Channel 2 Self-study output range
4x173
Channel 3 Self-study output range
4x174
Channel 4 Self-study output range
4x175
Channel 5 Self-study output range
4x176
Channel 0 Temperature difference
Unit: 1ºC
4x177
Channel 1 Temperature difference
Unit: 1ºC
4x178
Channel 2 Temperature difference
Unit: 1ºC