SERIAL PROTOCOL 

 

USER’S MANUAL 

SWEEP

 V1.0 

 

Copyright ©2014-2017 Scanse LLC - www.scanse.io 

Command Symbol:

 2 byte code at the beginning of every command (ASCII) 

 

 

 
 
 
 
 
 
 
 
 
 
 

 
Parameter:

 Information that is needed to change sensor settings (ASCII).. Example: a motor speed code 05 

transmitted as ASCII parameter '05', which has byte values [48, 53] in decimal. 
 

Line Feed (LF) or Carriage Return (CR):

 Terminating code. Command can have LF or CR or both as termination code 

but receipt will always have LF as its termination code. 
 

Status:

 2 bytes of data used to convey the normal/abnormal processing of a command. ASCII byte values 

of '00' or '99' indicate that the sensor received and processed the command normally. Value of '11' specifies an 
invalid parameter was included in the command. Any other byte values are reserved for communicating other 
errors or failure that are command specific. Usually these indicate a failure to process the command, often for 
valid reasons. 
 

Sum of Status:

 1 byte of data used to check for corrupted transmission. See Appendix for instructions for 

authenticating receipts.  
 
 

ASCII Code (2 bytes)  Function 

DS

 

Start data acquisition 

DX

 

Stop data acquisition

 

MZ 

Motor Ready 

MS

 

Adjust Motor Speed

 

MI

 

Motor Speed Info

 

LR 

Adjust LiDAR Sample Rate 

LI 

LiDAR Sample Rate Info 

IV

 

Version Info

 

ID 

Device Info 

RR 

Reset Device 

Содержание Sweep V1

Страница 1: ...cal drawings 0 9 12 19 2016 Initial Release Laser Safety 0 Power Safety 0 Specifications 2 Physical 2 Electrical 2 Measurement Performance 2 Field of View 2 Measurement Error Test Data 2 Overview of I...

Страница 2: ...see Theory of Operation Sweep is a single plane scanner This means that as its head rotates counterclockwise it records data in a single plane The beam starts out at approximately 12 7mm in diameter a...

Страница 3: ...e internal pull up Pull down to put device in sleep mode 3 Yellow Sync Device Ready Goes high when first range measurement of new scan is completed then goes low when second range measurement is compl...

Страница 4: ...Sudden rotational shocks can cause the head to either slow down or speed up which can affect angular measurements If Sweep is rotationally jerked hard enough it can cause the motor to lose sync which...

Страница 5: ...e Under normal operation Sweep limits the maximum time per measurement to a value determined by the sample rate set using the LR command see LR packet structure description If not enough light is retu...

Страница 6: ...with ASCII letter command codes HOST SENSOR Command with no parameter Command Symbol 2 bytes Line Feed 1 byte Example DS DX MI IV Line Feed LF or Carriage Return CR or Command with parameter Command...

Страница 7: ...al processing of a command ASCII byte values of 00 or 99 indicate that the sensor received and processed the command normally Value of 11 specifies an invalid parameter was included in the command Any...

Страница 8: ...ation about a single sensor reading Sync Error Byte The sync error byte is multi purpose and encodes information about the rotation of the Sweep sensor as well as any error information Consider the in...

Страница 9: ...e measurements This calibration routine is initiated after powering on the device after receiving any form of Adjust Motor Speed MS command regardless of the size of the adjustment ie even calling MS...

Страница 10: ...z 08 8Hz 09 9Hz 10 10Hz MS command is not guaranteed to succeed There are a few conditions where it will fail In the event of a failure the two status bytes are used to communicate the failure Status...

Страница 11: ...Hz LR command is not guaranteed to succeed There are a few conditions where it will fail In the event of a failure the two status bytes are used to communicate the failure Status Code 2 byte ASCII cod...

Страница 12: ...LF Example IVSWEEP01011100000001 I V SWEEP 01 01 1 00000001 LF Returns details about the device s current state settings Bit Rate Laser State Mode Diagnostic Motor Speed Sample Rate HOST SENSOR I D L...

Страница 13: ...s 0x30 return sum checkSumByteValue Example Consider the common case of 00P decimal 48 48 80 hex 0x30 0x30 0x50 0x30 0x30 0x60 sum of the status bytes 0x60 0x3F 0x20 retrieve only the lower 6 bits 0x2...

Страница 14: ...e sum of 6 other bytes Instead the checksum byte uses the modulo operation and effectively contains the remainder after dividing the sum by 255 this is the same as saying sum 255 Validating the checks...

Отзывы: