5.6
Trouble shooting
5.6.1 Common faults
Symptom
Cause
Correction
A
6
The machine won’t start
There is a power failure from the power supply
Inspect the fuses in the worksites fuse box
Inspect cables
Measure that all three phases are present and at full voltage
near the machine
O
E
E
The emergency stop button is depressed
Release the emergency stop button.
O
Internal error
If possible, read the alarm or fault code present at the display
inside of the electrical cabinet. Alarm codes are formatted as
“Axxxx” where “x” is the number. Fault codes are formatted
as “Fxxxx”.
Contact Scanmaskin Sweden AB
O
The machine is weak and
might stop when on the
ground.
One of the three phases are missing from the
power supply
There is a voltage drop at the power supply
Inspect the display on the inverter for any alarm code
Inspect the fuses in the worksites fuse box
Inspect cables
Measure that all three phases are present and at full voltage at
the cable end near the machine.
Make sure that the cable is not to long. If the cable should be
to long, use a cable with higher rating to a distribution box
nearer the machine.
O
O
E
E
O
The machine vibrates a lot
The grinding speed is to high
Lower the speed
O
The tools are damaged
Inspect the tools
Change the tools if needed
O
O
Table 51
Common faults
5.6.2 Error codes
Code
Description
Cause
Correction
A
7
A2001
Over current
One of the three phases is missing from the power
supply
There is a voltage drop at the power supply
Inspect the fuses in the worksites fuse box
Inspect cables
Measure that all three phases are present and at
full voltage at the cable end near the machine
Make sure that the cable is not to long. If the cable
should be to long, use a cable with higher rating to
a distribution box nearer the machine
O
O
E
E
The environmental temperature is too high. When
the temperature is above 40°C (104°F) the inverter
will decrease its maximum output current
Inspect the ventilation fans
Inspect the filters to the fans
O
O
A2002
Over voltage
The power supply has got voltage transients
Inspect the power source
E
A2003
Under voltage
One of the three phases is missing from the power
supply
There is a voltage drop at the power supply
See A2001
A2006
Speed reference
error
The potentiometer on the control panel is damaged
Inspect the potentiometer
Replace if necessary
S
S
A2009
Over temperature
The internal temperature in the inverter is above
120°C (248°F). This could be caused by faulty
ventilation in the electrical cabinet.
Inspect the ventilation fans
Inspect the filters to the fans
Contact Scanmaskin Sweden AB
O
O
A5001
Internal error
Contact Scanmaskin Sweden AB
F0001
Over current
See A2001
F0002
Over voltage
See A2002
F0003
Over temperature
The internal temperature in the inverter is above
135°C (275°F). This could be caused by faulty
ventilation in the electrical cabinet.
See A2009
F0004
Short circuit in
motor
The cable to the motor has been damaged
The motor has been damaged
Inspect the motor cable
Inspect the motor connection
Contact Scanmaskin Sweden AB
E
E
6
S
ee access table ”Table 53”
7
See access table ”
Table 53”
67
ENGLISH
www.scanmaskin.com
SCAN COMBIFLEX 500i/500PD
Содержание Scan Combiflex 500i
Страница 1: ...SCAN COMBIFLEX 500i 500PD MANUAL ...
Страница 31: ...6 1 1 2 Centrumaxel www scanmaskin se 31 SVENSKA SCAN COMBIFLEX 500i 500PD ...
Страница 33: ...6 1 1 4 Sliphuvud www scanmaskin se 33 SVENSKA SCAN COMBIFLEX 500i 500PD ...
Страница 39: ...NOTERINGAR NOTES www scanmaskin se 39 SVENSKA SCAN COMBIFLEX 500i 500PD ...
Страница 47: ...1 1 47 ENGLISH www scanmaskin com SCAN COMBIFLEX 500i 500PD ...
Страница 60: ...60 www scanmaskin com ...
Страница 73: ...6 1 1 2 Center axis Center axis SC 500 73 ENGLISH www scanmaskin com SCAN COMBIFLEX 500i 500PD ...
Страница 77: ...6 1 1 4 Grinding head 77 ENGLISH www scanmaskin com SCAN COMBIFLEX 500i 500PD ...
Страница 85: ...NOTERINGAR NOTES 85 ENGLISH www scanmaskin com SCAN COMBIFLEX 500i 500PD ...