FRESH AIR INTAKE

In a well-insulated house, the air used up by the burning process has to be replaced. This particularly applies to houses with 

mechanical ventilation. There are different ways of making sure that an air exchange takes place. The most important thing is to 

ensure that there is a supply of air to the room where the wood stove is located. The external wall vent must be located as close 

to the wood stove as possible, and you must be able to close it when you are not using the wood stove. Beware that the valve in 

the outer wall cannot be covered by accident!
National and local building regulations must be followed with regard to the connection of fresh-air intake.

CLOSED COMBUSTION SYSTEM

You should use the closed combustion system for the wood-burning stove if you live in a newly-built, airtight home.  

External combustion air is connected through a ventilation pipe via the wall or floor.
We recommend mounting a valve in the ventilation pipe in order to avoid condensate in the stove and the pipe system, which can 

be closed when the oven is not in use. It can also be an advantage to insulate the ventilation pipe.
Minimum Ø 100 mm ventilation pipe, maximum length: 6 metres with a maximum of 3 bends. We recommend smooth steel pipes.

NOTE: 

If the stove has a fresh air connexion or closed combustion, the ventilation pipe must be open, when the stove  

is in use!

MOUNTING OF EXTERNAL AIR SUPPLY

To dismount the cover plates for the Ø100 mm sleeve, use an ordinary screwdriver as shown below. Tilt the screwdriver and 

loosen the cover plates.

1

Содержание SCAN 1003-B

Страница 1: ...1003 B UK SCAN ASSEMBLY AND INSTRUCTION MANUAL SCAN 1003 B UK ASSEMBLY AND INSTRUCTIONS MANUAL SCAN 1003 B...

Страница 2: ...d we are sure that you will have years of pleasure from your purchase To make the best possible use of your stove it is important that you follow our advice and instructions Read through this Assembly...

Страница 3: ...all brackets 21 Mounting of the wall bracket 22 Mounting of combustion chamber 24 Adjustment of the door 26 INSTRUCTIONS FOR USE 27 CB technology Clean Burn 27 Baffle plate 27 Primary air 27 Secondary...

Страница 4: ...ave the installation inspected and approved by a local chimney sweep prior to commissioning SAFETY Any changes made to the product by the dealer fitter or user could result in the product and safety f...

Страница 5: ...h Fuel Wood Wood Fuel consumption 2 4 2 4 kg h Amount of fuel required to light 2 2 kg Amount of fuel max 3 3 kg Intermittent operation in this context means normal use of a wood burning stove In oth...

Страница 6: ...93 143 D A B C E D 6 DIMENSION SKETCH SCAN 1003 B A Top outlet B Rear outlet C Centre external air supply rear side D Centre of external air supply bottom E Height to the beginning of the connecting p...

Страница 7: ...174 314 5 1029 5 D B C E D A C 7 DIMENSION SKETCH SCAN 1003 B A Top outlet B Rear outlet C Centre external air supply rear side D Centre of external air supply bottom E Height to the beginning of the...

Страница 8: ...n contacting your dealer or Scan A S The product registration number is located at the back of the stove TYPE PLATE All Scan wood burning stoves are fitted with a type plate that specifies the approva...

Страница 9: ...2 x 6 5 mm Decor ring for top outlet Screw M5x6 Only used in Norway Baffle plates Burn chamber plates side and rear 3 pins 6 x 50 mm Eco energy label DISPOSAL OF PACKAGING Your Scan stove may come sup...

Страница 10: ...ag l se 12 08 2016 mbp Scan 1010 V GT AREAL N A N A 10 Large wall bracket Small wall bracket Large module is not to be used under the stove Small module Cover for fresh air inlet Large module with fre...

Страница 11: ...in the vicinity of your stove The floor plate s function is to protect the floor and flammable material against any sparks that may occur EXISTING CHIMNEY AND PRE FABRICATED ELEMENT CHIMNEY If you int...

Страница 12: ...nbjerg TG NR EMNE C Working Folder Designs Scan 1003 91003024 idw 91003024 M lskitse Scan 1003 B 23 05 2019 KEN Scan 1003 B V GT AREAL N A N A DIM Scan A S 649 564 5 572 324 5 324 5 188 291 479 82 93...

Страница 13: ...ETY DISTANCE European national and local regulations concerning safety distances for wood burning stoves and flue pipes must be complied with If you connect the stove to a steel chimney the safety dis...

Страница 14: ...m M bleringsafstand 800 mm Brandbart materiale Brandmur F eks 50 mm J tul firewall 14 Parallel rear wall installation 45 Corner installation DISTANCE TO FLAMMABLE MATERIALS DISTANCE TO FLAMMABLE MATER...

Страница 15: ...am 90064047 Brandmur og isoleret r gr r Scan 64 uden sideglas 29 08 12 BC V GT AREAL N A N A 100 50 50 960 700 700 253 1000 1000 0 0 15 Flammable material Fire wall e g 50 mm J tul Firewall 110 mm bri...

Страница 16: ...OPERATING THE DOOR 2 The door should be banged shut as on a car Grip the handle hold in a horizontal position and bang the door shut 1 Push down the handle and the door will open FITTING THE FLUE CON...

Страница 17: ...lve in the outer wall cannot be covered by accident National and local building regulations must be followed with regard to the connection of fresh air intake CLOSED COMBUSTION SYSTEM You should use t...

Страница 18: ...A DATO SIGN DK 5492 Vissenbjerg TG NR EMNE orking Folder Designs Scan 1003 91003041 idw 91003041 Ovn uden kasse 21 08 2019 ken Scan 1003 B V GT AREAL N A N A DIM Scan A S NAVN STI M3 NR MATERIALE DAT...

Страница 19: ...010036 idw 91010036 Frisklfuft bund 18 08 16 jm Scan 1010 V GT AREAL N A N A NAVN STI DIMENSION MATERIALE DATO SIGN Krog Iversen Co A S DK 5492 Vissenbjerg TG NR EMNE C Working Folder Designs Scan 101...

Страница 20: ...L N A N A Scan A S TG NR EMNE 91010015 justering af sokkel 1010 A 0 40 1 NAVN STI DIMENSION MATERIALE DATO Krog Iversen DK 5492 Vissen TG N EMNE C Working Folder Designs Scan 1010 91010039 idw indstil...

Страница 21: ...distances are in mm All distances are minimum distances WALL HUNG MODEL Installation must be planned and executed in accordance with national and local building regulations The stove must only be fit...

Страница 22: ...G NR EMNE C Working Folder Designs Scan 1010 91010048 idw 91010048 r gstuds 06 10 2016 hms Scan 1010 V GT AREAL 0 61 kg 69343 mm 2 DIM Scan A S A Scan 1003 B VE Freestanding room heater fired by solid...

Страница 23: ...0045 idw indikatorplade Scan 1010 V AREAL N A DIM NAVN STI M3 NR MATERIALE EMNE C Working Folder Designs Scan 1010 9101004 indikatorpla Scan 1010 A DIM 23 MOUNTING OF THE WALL BRACKET The smoke pipe s...

Страница 24: ...S DK 5492 Vissenbjerg TG NR EMNE C Working Folder Designs Scan 1003 91003033 idw 91003033 Montering af br ndkammersten 27 05 2019 ken Scan 1003 B V GT AREAL N A N A 24 MOUNTING OF COMBUSTION CHAMBER N...

Страница 25: ...B V GT AREAL N A N A 8 F G NAVN STI DIMENSION MATERIALE DATO SIGN Krog Iversen Co A S DK 5492 Vissenbjerg TG NR EMNE C Working Folder Designs Scan 1003 91003028 idw 91003028 Montering af nederste r gv...

Страница 26: ...GN TG NR EMNE 91005032 Justering af l ge 22 05 2018 ken 1005 V GT N A 26 ADJUSTMENT OF THE DOOR The door may hang a little over time This can be solved by adjusting the adjustment screw of the door up...

Страница 27: ...f the combustion chamber The plate holds back smoke making sure it stays inside the combustion chamber for a longer time before escaping through the chimney This reduces the flue gas temperature as th...

Страница 28: ...guide You should also follow the instructions in the specific manual for your stove model NOTE Never use liquid lighting fuels TOP DOWN LIGHTING Top down lighting is a more environmentally friendly w...

Страница 29: ...this can cause a heavy heat development liable to damage both stove and the surrounding walls We therefore recommend that you always observe the max recommended amount of fuel See under Technical Dat...

Страница 30: ...reduce the damper settings to restrict combustion in the stove a brickwork chimney will take longer to reach operating temperature than a steel chimney It is very important that the operating temperat...

Страница 31: ...n its length Wood that has been split dries faster STORING You need to store the sawn and split wood in a dry place for 1 2 years before it will be dry enough to burn Wood dries faster if you stack it...

Страница 32: ...Check the combustion chamber lining and the grate Check heat insulating materials Check the locking device COMBUSTION CHAMBER LINING Slight cracks can appear in the combustion chamber lining due to mo...

Страница 33: ...e note that the glass cleaner is not to get into contact with the gaskets as this can discolour the glass permanently The glass cleaner must not come into contact with the painted surfaces as these ca...

Страница 34: ...ets etc Chimney not drawing sufficiently Vacuum in the room EXCESSIVE SOOT BUILD UP IN CHIMNEY Poor burning more air is required Damp wood THE SURFACE OF THE STOVE IS TURNING GREY Over firing See Inst...