background image

SCAN DSA 6 & 7-5

1  

Regulation for primary air.

 

 

Push the button sideways.  Left position is closed and right 
position is open. The primary air is used when lighting and 
refuelling the stove. It should always be closed during conti-
nuous firing.

2  

Regulation for combustion air.

 

 

Push the button sideways. Left position is closed and right 
position is open. The air is used for the combustion and regu-
lates the output of the stove.

3  

Productionnumber 

SCAN DSA 7-5

Combustion air

Ceramic smoke deflectors

SCAN DSA 6

Ceramic smoke deflectors

Lift up the lower ceramic smoke deflector, pull out the pins in the 
lateral combustion chamber plates, and remove the deflector. The 
upper deflector is removed in the same way. 

Clean combustion

The SCAN DSA insert uses the "CB technique" (Clean-Burn) to 
ensure an optimally clean combustion. The extra combustion air 
is preheated and led into the combustion chamber close to the 
ceramic smoke deflector. 

You should read this manual as well as the 

General Instructions for Inatallation

 before beginning the installation.

Closed

Open

2

1

3

2

2

1

1