SCAN 5006-S FL Скачать руководство пользователя страница 35

35

WARRANTY

All wood-fired Scan products are made of high-quality materials and subject to strict quality controls before leaving the factory. 

We give a warranty of 5 years on manufacturing errors or defects.
You must quote your stove‘s product registration number when you contact us or your authorised Scan dealer with a warranty 

claim. 
The warranty covers all parts which in the opinion of Scan A/S require repair or replacement due to manufacturing or construc-

tion error
The warranty applies to the original purchaser of the product only, and is not transferable (except on prior sale). 
The warranty covers only damage caused by manufacturing or construction errors.

THE FOLLOWING PARTS ARE NOT COVERED BY THE WARRANTY

¬

  

Wear and tear parts, such as the combustion chamber liners, baffle plates, riddling grate, glass, and seals (except for defects 

which were present on delivery)

¬

  

Defects caused by external chemical and physical influences during transportation, storage and assembly, or at a later time

¬

 

Soot build-up caused by poor chimney draught, damp wood, or improper use

¬

 

Costs of additional heating in connection with a repair

¬

 

Transport costs

¬

 

Costs for setting up or removing the wood stove

THIS WARRANTY IS VOID

¬

  

 In case of incorrect installation (the installer is responsible for observing and complying with legal requirements and local 

bylaws, along with this Assembly- and Instructionsmanual for the wood-burning stove and accessories)

¬

  

In case of improper use, and/or use of prohibited fuels, non-original spares (see this Assembly- and instructions manual)

¬

 

If the product registration number of the stove has been removed or damaged

¬

 

In case of repairs that do not comply with our instructions or instructions by an authorised Scan dealer

¬

 

 In case of any manipulation of the original state of this Scan product or its accessories

¬

 

This warranty is only valid in the country to which this Scan product was originally supplied

Содержание 5006-S FL

Страница 1: ...5006 S FR FL UK SCAN ASSEMBLY AND INSTRUCTION MANUAL SCAN 5006 S FR FL UK ASSEMBLY AND INSTRUCTIONS MANUAL SCAN 5006 S FR FL...

Страница 2: ...ill have years of pleasure from your purchase To make the best possible use of your stove it is important that you follow our advice and instructions Read through this Assembly and Instruction Manual...

Страница 3: ...arge rooms 14 Heat storage system 14 Mounting of the heat shields convection covers 15 Before mounting of surrounding 19 Mounting of surrounding 20 INSTRUCTIONS FOR USE 27 Baffle plates 27 Ash contain...

Страница 4: ...e installation inspected and approved by a local chimney sweep prior to commissioning To ensure best possible functionality and safety for your installation we advise you to call a professional fitter...

Страница 5: ...mount of fuel required to light 1 4 kg Amount of fuel max 2 0 kg Materials Silicate plate Steel plate Cast iron Galvanised sheet Chamotte Surface treatment Senotherm Max log length 33 cm Weight Scan 5...

Страница 6: ...2 Back 272 320 900 900 360 Scan 5006 S 6 Floor plate All distances are in mm All distances are minimum distances Connection of fresh air intake inside measure 108 mm outside measure 125 mm Min distanc...

Страница 7: ...T AREAL N A N A DIM Scan A S 590 425 900 900 360 304 1693 50 304 50 7 Flammable material Fire wall e g 50 mm J tul Firewall 110 mm brick or other material with corresponding fireproof and insulating a...

Страница 8: ...is number at the rear page of this manual you will always need to quote it when contacting your dealer or Scan A S TYPE PLATE All Scan built in stoves are fitted with a type plate that specifies the a...

Страница 9: ...loor plates see page 10 Fresh air box see page 13 Connection pipe 100 mm Heat storage stones see page 14 Detachable handle DISPOSAL OF PACKAGING Your Scan built in stove may come supplied with the fol...

Страница 10: ...If you are placing the stove on a flammable floor you must comply with the national and local regulations on the size of any non flammable subsurface required to cover the floor around the stove Your...

Страница 11: ...Constructed Changed by SCAN A S DK 5492 Vissenbjerg Drawing number 95003222 17 06 2019 sr 24 Min mm 11 CONVECTION AIR Convection means that there is an air circulation ensuring that the heat is equall...

Страница 12: ...ansing lid must be placed in the vertical part so that the horizontal part can be cleaned through here If the chimney is fitted with a smoke extractor it must be possible to adjust it to a suitable dr...

Страница 13: ...f you want to use a 100 mm connection tube you can mount a gasket on the outside of the tube before mounting the tube inside the connection piece CLOSED COMBUSTION SYSTEM You should use the closed com...

Страница 14: ...TG NR EMNE C Working Folder Designs Scan 5003 95003019 idw 95003019 Spj ld clips til Norge large rums 13 07 2017 sr Scan 5003 V GT AREAL N A N A DIM Scan A S 70 kg 14 Mount the clips CLIPS FOR NORWAY...

Страница 15: ...ht Area N A N A Articlenumber Constructed Changed by B 0 40 1 B Stove Path Material Date SCAN A S DK 5492 Vissenbjerg Drawing number Name C Working Folder Designs Scan 5002 95002014 iam 95002014 Monta...

Страница 16: ...IM Scan A S A 1 2 NAVN STI M3 NR MATERIALE DATO SIGN DK 5492 Vissenbjerg TG NR EMNE C Working Folder Designs Scan 5003 95003010 idw 95003010 Montage af varmeskjold 11 07 17 SR Scan 5003 V GT AREAL N A...

Страница 17: ...AREAL N A N A Scan A S 6 B 1 4 NAVN STI M3 NR MATERIALE EMNE C Working Folder Designs Scan 5002 95002012 idw Montage at varmeskjold Scan 5002 V GT AREAL N A N A DIM 17 MOUNTING OF THE HEAT SHIELDS CO...

Страница 18: ...g Folder Designs Scan 5003 95003015 idw 95003015 Montage at varmeskjold 12 07 17 sr Scan 5003 V GT AREAL N A N A DIM Scan A S NAVN STI M3 NR MATERIALE DATO SIGN DK 5492 Vissenbjerg TG NR EMNE C Workin...

Страница 19: ...number Name C Working Folder Designs Scan 5003 95003057B idw 95003057B Montage af omramning 08 08 2019 ken Scan 5003 S FR FL Weight Area N A N A 19 BEFORE MOUNTING OF SURROUNDING Remember to cut out...

Страница 20: ...R FL Weight Area N A N A Tenso P14 2 Tenso P 14 Pre load Clip Stove Path Articlenumber Material Date Constructed Changed by SCAN A S DK 5492 Vissenbjerg Drawing number Name C Working Folder Designs Sc...

Страница 21: ...iclenumber Material Date Constructed Changed by SCAN A S DK 5492 Vissenbjerg Drawing number Name C Working Folder Designs Scan 5003 95003042 idw 95003042 Montage af omramning 30 04 2019 ken Scan 5003...

Страница 22: ...te Constructed Changed by SCAN A S DK 5492 Vissenbjerg Drawing number Name C Working Folder Designs Scan 5003 95003059 idw Montage af omramning 08 08 2019 ken Scan 5003 S FR FL Weight Area N A N A Sto...

Страница 23: ...ontage af omramning 08 08 2019 Scan 5003 S FR FL 9 8 11 10 Stove Path Articlenumber Material Date Constructed Changed by SCAN A S DK 5492 Vissenbjerg Drawing number Name C Working Folder Designs Scan...

Страница 24: ...S DK 5492 Vissenbjerg Drawing number Name C Working Folder Designs Scan 5003 95003053 idw 95003053 Montage af omramning 08 08 2019 ken Scan 5003 S FR FL Weight Area N A N A G Stove Path Articlenumber...

Страница 25: ...A N A Stove Path Articlenumber Material Date Constructed Changed by SCAN A S DK 5492 Vissenbjerg Drawing number Name C Working Folder Designs Scan 5004 95004211 idw 95004211 Omramning 05 07 2019 KEN S...

Страница 26: ...5003 95003046 idw 9 Montage af omramning 30 04 2019 ken Scan 5003 S FR FL Weight Area N A N A 24 25 27 26 D Date Constructed Changed by SCAN A S DK 5492 Vissenbjerg Drawing number Name r Designs Scan...

Страница 27: ...erial and are liable to break easily You should therefore handle them with care The baffle plates are subject to wear and tear and not coverec by the warranty ASH CONTAINER Open the door and the grate...

Страница 28: ...rrect top down lighting 4 pieces of wood approx 20 25 cm long with a weight of approx 0 4 0 5 kg per piece 12 20 thin pieces of firewood of about 20 25 cm in length with a total weight of approx 1 kg...

Страница 29: ...a flammable container Ashes can contain glowing embers long after you finish operating the stove When the stove is not in use you can close the dampers to avoid a draught through the stove If the stov...

Страница 30: ...ter than the above it should be split down its length Wood that has been split dries faster STORING You need to store the sawn and split wood in a dry place for 1 2 years before it will be dry enough...

Страница 31: ...Check all visible surfaces for cracks Check that all joints are tight and that the gaskets are correctly seated Worn or deformed gaskets should be replaced SERVICING We recommend that the stove is tho...

Страница 32: ...028 Brandkammerforing 08 01 2018 ken Scan 5003 V GT AREAL N A N A NAVN STI DIMENSION MATERIALE DATO SIGN Krog Iversen Co A S DK 5492 Vissenbjerg TG NR EMNE C Working Folder Designs Scan 5003 95003029...

Страница 33: ...his film by wiping the glass down with a dry cloth and then with a cloth dampened with glass cleaner Please note that the glass cleaner is not to get into contact with the gaskets as this can discolou...

Страница 34: ...awing sufficiently Vacuum in the room EXCESSIVE SOOT BUID UP IN CHIMNEY Poor burning more air is required Damp wood THE SURFACE OF THE BUILT IN STOVE IS TURNING GREY Over firing See Instructions for h...

Страница 35: ...t on delivery Defects caused by external chemical and physical influences during transportation storage and assembly or at a later time Soot build up caused by poor chimney draught damp wood or improp...

Страница 36: ...36 NOTES...

Страница 37: ...37...

Страница 38: ...38...

Страница 39: ...39...

Страница 40: ...26 11 2021 SCAN A S Damsbovej 1 DK 5492 Vissenbjerg www scan stoves com Edition UK 95006501 10059355 P02 Product registration number Quote this number at all enquiries...

Отзывы: