MAINTENANCE
SWEEPING THE CHIMNEY AND CLEANING THE STOVE
Follow national and local regulations for sweeping the chimney. We recommend having the stove cleaned regularly by a chimney
sweep.
Before cleaning the stove and sweeping the chimney, the baffle plates must be removed.
NOTE: All service and reparation must be done, when the stove is cold.
CHECKING THE STOVE
Scan A/S recommends that you check your stove thoroughly after sweeping/cleaning. Check all visible surfaces for cracks.
Check that all joints are tight and that the gaskets are correctly seated. Worn or deformed gaskets should be replaced.
SERVICING
We recommend that the stove is thoroughly serviced at least every two years by a qualified fitter. Remember only to use original
spare parts.
The service should include the following:
¬
Lubricate hinges using copper grease
¬
Check the gaskets. Replace any that are broken or have turned hart
¬
Check the combustion chamber lining and the grate
¬
Check heat-insulating materials
COMBUSTION CHAMBER LINING
The combustion chamber lining is not covered by the warranty.
The lining consists of the following parts:
¬
9 chamotte plates (1, 3 & 4)
¬
1 grate (2)
¬
2 baffle plates (5 & 7)
¬
1 fitting for baffle plate (6)
Combustion chamber lining
Max load