NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 1001\91001025.idw
91001025
Montage røgstuds
26-04-12
BC
Scan 1001
VÆGT:
AREAL:
N/A
N/A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 1001\91001025.idw
91001025
Montage røgstuds
26-04-12
BC
Scan 1001
VÆGT:
AREAL:
N/A
N/A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 1005\91005028.idw
91005028
Montage røgstuds
16-11-2018
KEN
Scan 1005
VÆGT:
AREAL:
N/A
N/A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 1005\91005028.idw
91005028
Montage røgstuds
16-11-2018
KEN
Scan 1005
VÆGT:
AREAL:
N/A
N/A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 1005\91005028.idw
91005028
Montage røgstuds
16-11-2018
KEN
Scan 1005
VÆGT:
AREAL:
N/A
N/A
18
4 x flange nuts M6
Mount the gasket 3 x 8 mm at the edge of the flange of the connecting piece. Fasten the connecting piece with the flanged nuts
Gasket
FRESH AIR INTAKE
In a well-insulated house, the air used up by the burning process has to be replaced. This particularly applies to houses with
mechanical ventilation. There are different ways of making sure that an air exchange takes place. The most important thing is to
ensure that there is a supply of air to the room where the wood stove is located. The external wall vent must be located as close
to the wood stove as possible, and you must be able to close it when you are not using the wood stove.
National and local building regulations must be followed with regard to the connection of fresh-air intake.
CLOSED COMBUSTION SYSTEM
You should use the closed combustion system for the wood-burning stove if you live in a newly-built, airtight home.
External combustion air is connected through a ventilation pipe via the wall or floor.
We recommend mounting a valve in the ventilation pipe in order to avoid condensate in the stove and the pipe system, which can
be closed when the oven is not in use. It can also be an advantage to insulate the ventilation pipe.
Minimum Ø 100 mm ventilation pipe, maximum length: 6 metres with a maximum of 3 bends. We recommend smooth steel pipes.
NOTE:
If the stove has a fresh air connexion or closed combustion, the ventilation pipe must be open, when the stove
is in use!
FITTING THE FLUE CONNECTION PIECE
The insert is prepared for a top flue outlet from the factory, but the connection piece can be turned around for a rear outlet.
Mount the connecting piece on the insert, after it has been placed in the cassette.
If the radiation plate was removed before the mounting, remember to put it back in place before putting the burn chamber back
into the cassette.
Radiation plate