background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

e

e

N

N

o

o

d

d

3

3

-

-

D

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

D

i

i

g

g

i

i

t

t

a

a

l

l

 

 

d

d

o

o

s

s

i

i

n

n

g

g

 

 

c

c

o

o

n

n

t

t

r

r

o

o

l

l

l

l

e

e

r

r

 

 

e

Nod3-

D

 : User’s instructions 

165 752-A 

1/23 

²  
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 

User’s instructions

 

Содержание eNod3-D

Страница 1: ...e eN No od d3 3 D D D Di ig gi it ta al l d do os si in ng g c co on nt tr ro ol ll le er r eNod3 D User s instructions 165 752 A 1 23 User s instructions...

Страница 2: ...mode 12 7 4 Feeding mode in dosing processes 13 8 SET POINTS 13 9 FILTERS 13 10 TRANSMITTER FUNCTIONING MODE 14 10 1 Measurement reading request 14 10 1 1 Single measurement transmission 14 10 1 2 Con...

Страница 3: ...12 2 2 Verification of the available product quantity 22 12 2 3 Start delay 22 12 2 4 Coarse feed effect neutralization time 22 12 2 5 Fine feed level 22 12 2 6 Fine feed effect neutralization time 2...

Страница 4: ...ts transmitter dosing by filling dosing by unloading eNod3 D is equiped with RS485 422 RS232 and CANbus outputs supporting ModBus RTU SCMBus and CANopen protocols Each module is also provided with 2 d...

Страница 5: ...ltage 0 3 VDC high level voltage 9 28 VDC current at high level 10mA 24V mA insulation voltage 2500 Vrms Logical outputs number 4 type opto insulated static relays max current 40 C 0 4 A max voltage i...

Страница 6: ...t the power supply is correctly connected 2 2 Connection to load cell s eNod3 D supplies power to the load cells 5 VDC Up to four 350 load cells can be connected in parallel eNod3 D allows the use of...

Страница 7: ...ection to a detector connection to a push button PB 2 3 2 Digital outputs Opto insulated inputs characteristics high level 9 to 28VDC Consumption 10mA 24VDC low level 0 to 3 VDC Opto insulated outputs...

Страница 8: ...eception RB inverse reception For an RS485 half duplex communication just connect the TB and TA pins and remove the corresponding jumper OFF For an RS422 or RS485 full duplex communication use the fou...

Страница 9: ...is based on the master slave structure however it allows to transmit measurements continuously without collision management on the line This operating mode is only available in transmitter functioning...

Страница 10: ...Physical calibration using known references on the load cell This type of calibration can be done with 1 2 or 3 known loads Theoretical adjustment by setting the load cell sensitivity and a correspon...

Страница 11: ...no effect tare one or the other or both inputs can be assigned to the tare function The tare acquisition is conditioned by a stability criterion that can be changed or inhibited Depending on the choos...

Страница 12: ...le set points cf 8 Output 1 is assigned to set point 1 output 2 to set point 2 output 3 to set point 3 and output 4 to set point 4 Motion The outputs can be assigned to copying measurements stability...

Страница 13: ...nd order band stop filter self adaptive filter Filtering related to the A D conversion rate the signal resolution is related to the conversion rate The conversion rate might be choosen as low as possi...

Страница 14: ...lar positive analog signal only or bipolar positive or negative analog signal 10 1 Measurement reading request 10 1 1 Single measurement transmission Regarless of the communication protocol in use The...

Страница 15: ...5 This is only possible using standard or fast SCMBus The request can apply to gross measurement net measurement measurement in A D converter points While the input is kept at the right level a serie...

Страница 16: ...ess is entirely managed by eNod3 D and especially thanks to its four digital outputs allowing to monitor the different phases of the cycle and to indicate errors Fig 6 and 7 shown below represent grap...

Страница 17: ...ion of a start cycle command or the activation rising or falling edge depending on the logic of a digital input assigned to this function the filling cycle starts as soon as the start delay has elapse...

Страница 18: ...minimal value If it is not the case an output assigned to dosing failure or flow rate failure is set and the cycle is suspended if the cycle recovery option is active else it is stopped The flow rate...

Страница 19: ...s are activated If the use FF if out of low tolerance is active the fine feed is restarted If the updated result is out of tolerances and if the automatic inflight correction option is active the infl...

Страница 20: ...ight in loss from a tank equiped with a load cell In this functioning mode the dosing process is entirely managed by eNod3 D and especially thanks to its four digital outputs allowing to monitor the d...

Страница 21: ...eloading holding time 2 start delay 3 motion time out 4 coarse feed effect neutralization time 5 fine feed effect neutralization time cycle in progress reloading dosing result available start cycle Fi...

Страница 22: ...ined by two parameters a time interval if 0 the flow rate control is not used a minimal weight variation 12 2 2 Verification of the available product quantity At every cycle start eNod3 D checks that...

Страница 23: ...ce target weight dosing result tol rance where target weight dosing result 0 the out of tolerances and dosing failure outputs are activated If the use FF if out of low tolerance is active the fine fee...

Отзывы: