2、Baud Rate Setting 

Second 8-bit DIP switch B2 4,5 for the ball set the baud rate, the 

baud rate can be set 2400BPS, 4800BPS, 9600BPS, 19200BPS. Each switched 

to ON to OFF value is 1, the value is 0, the baud rate with DIP switches 

corresponding to Table 3。 

Table 3: baud rate DIP switch correspond 

DIP switch 

2400 bps 

4800 bps 

9600 bps 

19200 bps 

# 4 

OFF 

ON 

OFF 

ON 

# 5 

OFF 

OFF 

ON 

ON 

Under control of the ball equipment communication baud rate DIP 

switch settings in Table 3。 

 
3、Protocol settings 

 

The  ball  decoder  board  automatic  matching  agreement,  without 

setting; Supported protocols are PELCO_D, PELCO_P。 

Содержание PTA1326X

Страница 1: ...Camera lntegrared speed dome Installation and user manual Before Dome integrated camera please read this manual ...

Страница 2: ...pany for free repair or replacement parts Without the company s agreed to not disassemble the repair In addition to housing bracket and external wire repair and replacement during the warranty period other parts are subject to damage or failure by the company s technical staff confirmed to occur under normal use the Company will provide free repair and replacement devices The following situations ...

Страница 3: ...ers and and so on on led to the failure and damage Special note to achieve the full functionality of our products third party products used in the system must be tested for compatibility 2 product characteristics 9 inch sphere nice cover overall with the rotation of the ball machine infrared light is completely obscured by the dome under the ball of the independent body as a whole pitching rotatio...

Страница 4: ...wing angle infrared light irradiation angle different from the current camera viewing angle and the produce phased rest lower operating current of the control panel of the infrared light heat components the dark current has been effectively controlled has greatly improved the working environment of the integrated camera improve the whole of the true meaning of life and stability decoder board inte...

Страница 5: ... DC12V 200mA Camera supply DC12V 500mA The installation of temperature control equipment Operating temperature range 5 C 69 C Address range 0 255 Communication RS485 bus control mode Communication protocol supports multiple communication protocols Baud Rate 2400bps 4800bps 9600bps 19200bps adjustable Control equipment video matrix industrial DVR DVR control keyboard Preset points 128 preset points...

Страница 6: ...ction 1 Ball machine signal power cable connection see Figure 5 Address protocol baud rate setting Infrared dome built in decoder board decoder board address protocol baud rate settings on the dome PTZ camera lens control This product is designed DIP switch is located on the inside the sphere taking into account the convenience and stability of the set below the upper dome designed one can be open...

Страница 7: ... 1 to OFF value is 0 the address shown in Table 2 Table 2 address coding DIP switch correspond binary this table estimates Binary addr ess Binary add res s Binary add res s Binary add res s 0000000 0 11110000 15 01111000 30 10110100 45 10000000 1 00001000 16 11111000 31 01110100 46 01000000 2 10001000 17 00000100 32 11110100 47 11000000 3 01001000 18 10000100 33 00001100 48 00100000 4 11001000 19 ...

Страница 8: ...11 250 11011111 251 00111111 252 10111111 253 01111111 254 11111111 255 2 Baud Rate Setting Second 8 bit DIP switch B2 4 5 for the ball set the baud rate the baud rate can be set 2400BPS 4800BPS 9600BPS 19200BPS Each switched to ON to OFF value is 1 the value is 0 the baud rate with DIP switches corresponding to Table 3 Table 3 baud rate DIP switch correspond DIP switch 2400 bps 4800 bps 9600 bps ...

Страница 9: ... by control keyboard hard disk recorders and other control equipment to the infrared ball to move to the appropriate location by controlling the zoom buttons of the keyboard hard disk recorders and other control equipment to a suitable angle lens multiples of the reference control bit preset settings and enter the appropriate preset number For example the use of a particular model control keyboard...

Страница 10: ...he auto tour route Through the control keyboard hard disk recorders perform call preset 41 bit you can make the ball machine in the first cruise line automatic inspection has been set in the preset position and call preset 42 bit for automatic inspection the second cruise line in the preset position The eight patrol routes corresponding preset number shown in Table 6 Example using a model to contr...

Страница 11: ...conds a set preset key then enter 54 b click OK button 3 Clear the automatic inspection lines Clear automatic inspection line is actually the preset position in the provision patrol line all clear the operation mode by controlling the keyboard hard disk recorders implementation set presets 41 bit to clear the ball machine first cruise line all preset set preset 42 bit to clear the ball the No 2cru...

Страница 12: ... deviation you can move the dome camera to the zero bit by executing the command call preset 34 bit to restore the standard state 3 left and right limit auto scan scan speed settings enable and clear The infrared ball conductive ring and optical limit the factory default is 360 degrees continuous rotation the background of the control keyboard hard disk recorders ball left and right rotation limit...

Страница 13: ... controlling the keyboard or DVR implementation of the call preset 38 bit command does not have a left and right limit auto scan function causes the ball to the 360 degree continuous rotation of the machine set the left and right limit will automatically limit the scan back and forth between two points Example Using a model control keyboard to enable automatic scanning a call a preset key then ent...

Страница 14: ...vel of speed Set command Level of speed Set command 6 sec Set 61 preset 9 sec Set 62 preset 15 sec Set 63 preset 40 sec Set 64 preset Example the use of a particular model to control the keyboard to set the scan level speed of 9 degrees sec a set preset key then enter 62 b click OK button 4 restore factory settings Call 115 preset commands to be performed by controlling the keyboard or DVR ball ma...

Страница 15: ...ower are not allowed to borrow external rotation 3 DIP switch on the bottom of the dome open the pinch to address code and baud rate adjustment has not been allowed to do not open the dome 4 In order to ensure the accuracy of the preset in the setup to ensure the preset position in the left and right limit within the preset set the left and right limit 5 If a long time automatic inspection after p...

Страница 16: ...ot match it is in a resting state 7 The machine with the ordinary high speed ball preset also with lens preset setting method please refer to presets 8 ball machine outlet in order to avoid the connector outlet for the high temperature of the conductive ring line please do not force to pull the output cable CCTV SYSTEMS ...

Страница 17: ......

Отзывы: