8
/
10
SC POWER – SCB90Pro24
SC POWER – SCB90Pro24
Step 5
Take off the clip Indication:
Not any indicator lights are on
Make sure your Mini Jump Start was powered off first then,
①
Take off the black clip (-‐)
②
Take off the red clip (+)
ATTENTION!
1.
The activity of engine cranking will be limited in 3 seconds, it will cut off automatically in case failed to ignite. After
15 seconds, resume again for next crank attempt (maximum of 10 times cranking is advised, otherwise the device
might potentially be damaged.)
2.
The car engine successfully started, please press the power button to turn off the device A.S.A.P.
3.
Always re-‐charge the device after use or and make sure it is fully re-‐charged before use.
4.
Please be ensured that the polarity is connected correctly, otherwise it will damage the device! The supplier is not
responsible for damages caused by improper connection and / or operation.
OPERATION ON THE CAR WITH A DEAD BATTERY
Indication:
S.O.S / JUMP START RED LIGHT FLASH
Hold the Jump Start and Light / S.O.S buttons simultaneously
for 3 sec.
Please make sure the polarity is connected correctly
before those buttons are pressed, otherwise the device will be
severely damaged.