11
SBS-6500 User Manual
Storage Battery Systems, LLC.
SD High Capacity Memory
All measurement data (7,530,000 data blocks) including resistance, voltage, temperature,
currents, comparator result and specific gravity (data upload from SBS-2003 gravity tester
via Bluetooth) can be saved in the internal SD memory of the SBS-6500. This capacity
allows a history archive of:
String
(Bank)
Max 301 (including 1 auto string )
No: 000 - Reference DB not registered and open default string
No: 001 - 300: Reference DB comparison registered
Cells
Max 250 cells per string
Test
100 measurements for each cell/battery over its life.
Auto Saving
In AUTO REC the measurement data is automatically saved in the internal memory.
Maximum of 250 cells’ data can be saved in order. The saved data can be transferred to
any assigned address in the string record memory or can be removed.
PC Interface - Functional Control through PC
Any of the data stored in the internal memory of the SBS-6500 can be reviewed on the
hand held unit directly via the data menu or by connecting the unit to the PC with the
supplied USB cable and using the SBS Battery Link Software. All data in the memory can
be reviewed, printed or exported via the software interface that comes with the unit. The
software also allows direct input of string set-up and programming of the Reference DB
while the SBS-6500 is connected to the software.
Back up and restoration of the entire memory is available under the FILE tab in the
software. It is recommended that the SBS-6500 memory is backed up after initial
programming of the unit, after maintenance activities are completed and prior to sending
the unit in for calibration, evaluation or repairs.
The functional controls of the SBS-6500 are mimicked on the software allowing for
selection, entry and saving of programming features.