Currency Discrimination Fitness Sorter SB – 2000EX Service Manual
72
14. Maintenance
Assy_Block_Tape_Detector is the part that is apt to be accumulated by much dust including
powder of notes and even metallic particles etc. So it is necessary for periodically clearing
dust.
Dust is one of reason makes shortage of circuit board.
Following pictures show how to clear dust.
Open the Rear Door.
Wipe the Roller_Detect_Tape with cotton flannel
or soft cloth
Spout depressed air into the dust duct
penetrated through the Case_Detect with Dust Air
Blower or Aerosol.
At the opposite side do in the same way.
Содержание SB-2000EX
Страница 74: ...Currency Discrimination Fitness Sorter SB 2000EX Service Manual 73 15 Board Component 15 1 Connection Diagram...
Страница 76: ...Currency Discrimination Fitness Sorter SB 2000EX Service Manual 75 Bottom Side...
Страница 80: ...Currency Discrimination Fitness Sorter SB 2000EX Service Manual 79 Bottom Side LINE DRIVER...