COMMISSION REGULATION (EU) 2015/1188 

 

Requirements for product information applicable to commercial local space heaters 

 

Luminous heaters RI 

 

Model identifier 

RI 

RI 

RI 

10 

RI 

12 

RI 

16 

RI 

20 

RI 

20-2 

RI 

24 

RI 

24-2 

RI 

32 

RI 

32-2 

RI 

48-2 

RI 

64-2 

Type of heating 

Luminous heaters 

Fuel 

Gaseous 

Space heating emissions

 

NO

x

 emissions (mg/kWh 

PCS

< 50 

Heat input 

Nominal heat input (kW 

PCS

2,8 

3,7 

4,2 

5,7 

7,5 

8,4 

8,4 

11,4  11,4  15,0  15,0  22,5  30,0 

Minimum heat input e (kW 

PCS

n.d 

n.d 

n.d 

n.d 

n.d 

n.d 

4,2 

n.d 

5,7 

n.d 

7,5 

15,0  15,0 

Minimum heat input e (% of P

nom

n.d 

n.d 

n.d 

n.d 

n.d 

n.d 

50 

n.d 

50 

n.d 

50 

66 

50 

Radiant factor

 

Radiant factor at nominal heat output 

0,65  0,65  0,64  0,64  0,63  0,64  0,64  0,64  0,64  0,63  0,63  0,63  0,63 

Radiant factor at minimum heat output 

n.d 

n.d 

n.d 

n.d 

n.d 

n.d 

0,64 

n.d 

0,64 

n.d 

0,63  0,63  0,63 

Auxiliary electricity consumption

 

At nominal heat input (kW) 

0,019  0,019  0,019  0,019  0,019  0,019  0,038  0,019  0,038  0,019  0,038  0,038  0,038 

At minimum heat input (kW) 

0,019  0,019  0,019  0,019  0,019  0,019  0,019  0,019  0,019  0,019  0,019  0,019  0,019 

In standby mode (kW) 

Heat output control type

 

Single stage 

Yes 

Yes 

Yes 

Yes 

Yes 

Yes 

No 

Yes 

No 

Yes 

No 

No 

No 

Two stages 

No 

No 

No 

No 

No 

No 

Yes 

No 

Yes 

No 

Yes 

Yes 

Yes 

Modulating 

No 

No 

No 

No 

No 

No 

No 

No 

No 

No 

No 

No 

No 

Seasonnal efficiency

 

Seasonnal space heating efficiency 

85,9 

85,9 

85,4 

85,4 

85,0 

85,4 

87,8 

87,8 

85,4 

87,8 

87,3 

87,3 

87,3 

 

 

Содержание RI 6

Страница 1: ...Norge 21490 CLENAY FRANCE http www sbm international net 1 GAS INFRARED HEATERS RI 6 8 10 12 16 HEATERS USER INSTRUCTIONS Nr 05000309 5 1 PRODUCT SPECIFICATION 2 SAFETY RECOMMENDATIONS 3 IGNITION 4 SH...

Страница 2: ...12 AP 230 1312 AP 231 1312 AP 231 1312 AP 232 Class NOx 4 Weight kg 3 00 3 40 3 60 3 90 4 40 Net calorific value Qn kW Hi 2 50 3 30 3 80 5 10 6 75 Combustion air G20 m3 h G31 2 60 2 30 3 40 3 10 3 90...

Страница 3: ...MECHANICAL CONSTRAINTS ON THE RADIANT IT IS RECOMMENDED THAT IT BE CONNECTED TO THE GAS MAINS BY A FLEXIBLE TUBE TO BE INSTALLED IN WELL VENTILATED PREMISES NOT FOR DOMESTIC USE 2 1 HEATER INCLINATION...

Страница 4: ...e power off and call your SBM installer Automatic control VisioLon Ind I control module Open the main gas valve Switch the power on Check the settings temperature time Change module programming if nec...

Страница 5: ...actor Radiant factor at nominal heat output 0 65 0 65 0 64 0 64 0 63 0 64 0 64 0 64 0 64 0 63 0 63 0 63 0 63 Radiant factor at minimum heat output n d n d n d n d n d n d 0 64 n d 0 64 n d 0 63 0 63 0...

Страница 6: ...TO BE DISPLAYED NEXT TO THE CONTROL UNIT...

Страница 7: ...If the flame is not lit after 30 seconds the heater goes to safety state The sequence of ignition can begin again only after switching the power off After 5 seconds switch the power on The heater is o...

Страница 8: ...I module START UP Open the main gas valve Switch the power on Check the settings temperature time Change module programming if necessary The module automatically controls the ignition and the extinct...

Отзывы: