6. Important notices
6.1. Maintenance
The Ekinox does not require particular maintenance when operated in normal conditions. Nevertheless, if
you would like to maintain your sensor performance to the highest level, SBG Systems can provide a
maintenance service with regularly planned checkups and calibrations.
When used in harsh environments, please use damp clothes to clean the surface of the Enclosure.
Although not recommended, it is possible to use the Ekinox in salt water environments. In such
environments, the Ekinox enclosure must be rinsed with clear water to remove any long term presence of
salt on the enclosure.
6.2. Absolute maximum ratings
Stresses above those listed under the Absolute Maximum Ratings may cause permanent damage to the
device. This is a stress rating only; functional operation of the device at these or any other conditions above
those indicated in the operational section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
Parameter
Rating
VDD – GND
+/- 36 V
Galvanic isolation:
Power supply connector to chassis ground
Main connector GND to chassis ground
Extended connector to chassis ground
+/- 200 V
Rx+, Rx-, Logic inputs pins input voltage to signal GND
±25 V
Sync Out max current
30mA
Short circuit protected
Logic output Max current
150 mA
CANH, CANL
±80 V
Shock
500 g for 0.3 ms
Operating temperature range
-40 to 75°C (-40 to 167°F)
Storage temperature range
-40 to 85°C (-40 to 185°F)
Table 1: Absolute maximum ratings