Apogee Subsea
– Hardware Manual
APOGEESUBSEAHM.1.1
3. Mechanical specifications
3.1. Overview
The Apogee Subsea enclosure is composed of titanium parts, one for the cover and one for the base plate.
The device uses high quality alloys and connectors to offer a depth rating of 200 m, and good resistance to
seawater environment.
3.1.1. Main Specifications
The table below summarizes all mechanical and environmental specifications.
Specifications
Depth Rating
200m
Weight in air
2.1 Kg
Weight in water
0.95 Kg
Diameter
9.2 cm
Height
17.0 cm
Shocks
500 g for 0.3 ms
Operating Vibrations
1g RMS – 20Hz to 2 kHz as per MIL-STD-810G
Specified Temperature range
-20 to 60°C (-4 to 140°F)
Operating Temperature range
-40 to 71°C (-40 to 185°F)
MTBF (computed)
50.000 hours
Calibration interval
None required, maintenance free
3.1.2. Device mechanical alignment
For best measurement accuracy, a good mechanical alignment is required. During manufacturing, the
Apogee measurement frame has been carefully aligned to 0.02° with the base plate for roll, pitch and yaw
angles.
To ease the yaw alignment (X axis), the base plate features two alignment holes Ø 4 mm H8 that
guarantees with two taper pins Ø 4 mm h7 a yaw alignment better than ±0.04°.