Wiring

Check That

Commissioning

9. 

Ensure that the fitting is pushed into the ground correctly, and cannot fall over. Ensure that the fitting is 0.5m 
from the illuminated surface.

10.  Replace fuse or circuit breaker and switch on. Your light is now ready for use. 

Plug Fitting
1. 

The appliance must be connected to a 240 volts AC supply.

2. 

The appliance can be fitted to a rewireable 3 pin plug fitted 
with a 3 amp fuse. Should the fuse require replacement, it 
must be replaced with a fuse rated at 3 amp and approved to 
BS1362.

3. 

If the mains plug is unsuitable for the socket outlet or is 
removed for any other reason, then the cut off plug should be 
disposed of safely to prevent the hazard of electric shock.

There is a danger of electric shock if the cut off plug is inserted 
into any 13 amp socket outlet.

The wires in the mains lead on this appliance are coloured in 
accordance with the following code:
Blue – Neutral
Green / Yellow - Earth
Brown – Live

E

L

N

GREEN/ YELLOW

Earth

Neutral

Live

Fuse

3 Amps

Cord Clamp

BLUE

BROWN

If not fitting to a plug then the product must be wired to a IP44 rated terminal block.
Having correctly identified the wiring from your existing light fitting, connect to the approved outdoor rated 
external terminal block in the following way:

Check that.....
 You have correctly identified the wires.
 The connections are tight.
No loose strands have been left out of the connection block.
Enusre that all cord grips are tightly secured.
Eusure that all seals are re-fitted correctly.

NEUTRAL 

EARTH    

SWITCHED LIVE  

BLUE (N)

GREEN/YELLOW

BROWN (L)

SUPPLY

LIGHT FITTING

4th BLOCK PROVIDED FOR LOOP  

TERMINATION IF NECESSARY

SPOTLIGHTS GIVE A CONCENTRATED BEAM OF LIGHT AND MUST NOT BE POSITIONED 
ANY CLOSER THAN 0.5M (50CM) TO THE ILLUMINATED SURFACE.

0.5m