Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Warning
Specification
Voltage:
240V 50Hz a.c.
Lamp:
2.5W GU10 COB
IP rating:
44
Layout
Installation
Wiring
Existing fittings must be completely removed before
installation of a new product. Before removing the existing
fitting,
carefully note the position of each set of wires
.
•
Diagram A
. Determine the position of your light fitting
taking into account the exit position of the cable. Ensure
that the mounting surface is solid, preferably a brick or
block wall and ensure that there are no other cables or
pipes beneath the surface. Use appropriate fixings.
•
Separate the plastic back plate from the fitting by
removing the two domed nuts on the front of the fitting.
Leave the threaded (1) bolts in the back plate. Use the
back plate as a template to mark the screw holes. Make
sure the back plate is correctly aligned.
•
Diagram B.
Use a sharp object such as a screwdriver
to pierce the rubber grommet in the back plate. Feed
the incoming cable (2) through the rubber grommet and
attach the back plate to the wall. Do not over tighten as
this could damage the back plate.
•
Wire as detailed below.
• Plan the desired layout of this fitting carefully, ensuring
the cables will reach the distance between the junction
box and the light fitting.
• Avoid locating any cables in positions that would cause
a hazard. Position cables and outdoor rated junction
boxes (not supplied) away from areas where they may
be at risk from being cut, trapped or damaged.
• We recommend that you use H05RN-F specification
cable which is an outdoor grade, rubber sheathed cable.
The mains supply cable must have a minimum cross
sectional area of 1.0mm²
• Cables must be protected using suitable conduit or
plastic trunking.
SUPPLY
NEUTRAL
LIGHT FITTING
BLUE (N
)
BROWN (L)
SWITCHED LIVE
This light fitting is Double Insulated and
does not require connection to an Earth
circuit.
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure other
persons cannot restore the electrical supply without your
knowledge. If you are in any doubt, please consult a
qualified electrician.
This light fitting should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of the
connections.
This system contains non-replaceable parts and cannot be
serviced. If damage occurs the part should be scrapped.
Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist.
Check with your local authority or retailer for recycling
advice.
This product is rated at IP44.
This product is suitable for costal locations.
This product is not suitable for dimming.
Having correctly identified the wiring from your light fitting,
connect to the approved outdoor rated external terminal
block in the following way:
Diagram A.
Diagram B.
(1)
(1)
Internal
cable
s
(2)
Check that...
• You have correctly identified the wires
•
The connections are tight
• No loose strands have been left out of the connection
block.
•
Reseal the approved outdoor rated external terminal
block.