Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory 
operation of this product. Please retain these instructions for future reference.

Warning

 The LED modules are SELV, Class III fittings 

and must only be used with the 12v safety plug in 
transformer supplied. Under no circumstances must 
this transformer be replaced by a standard 13amp 
UK type plug. This will cause a safety hazard.

This IP65 rated product is only suitable for connection 
to a 240V~50Hz supply in accordance with current IEE 
wiring Regulations and should be installed to Part P, UK 
Building Regulations and is for Domestic use only.

The LED modules in this set can be fitted into a 
bathroom location – zones 1, 2 and outside zones BUT 
the transformer has no special protection against the 
ingress of water and must ALWAYS be plugged into a dry 
location, where there is no danger of it becoming damp.

If the set is to be used outdoors the transformer 
must ALWAYS be plugged in indoors.

Do not plug into the mains until your set is fully 

assembled.

This range of lights uses non-replaceable LEDs.

When planning a cable run ensure that the low voltage 
cable does not run alongside 240v mains cable.

Only use the cable supplied. Although this is low voltage 
cable it should be sited such that it is protected against 
mechanical damage, for example if it is to be used 
outdoors, by incorporating in a trench, of a suitable 
depth such that it will avoid any reasonably foreseeable 
ground disturbance, and identified by cable covers or with 
suitable marking tape etc.

The external flexible cable of this fitting cannot be 
replaced; if the cable is damaged, the fitting shall be 
destroyed.

If any modification is made it will invalidate the warranty 
and may render the product unsafe.

Specification

Power Supply: 

220-240V 50Hz. Output: 12V DC 6VA Max. Constant voltage

Lamp: 

6 x 0.2W Capsule (Orkney) Cool White

IP rating: 

65

Layout

Position the transformer next to the desired (indoor /dry) 
socket location – taking note of the length and positioning of 
the cable run. 

DO NOT PLUG IN THE TRANSFORMER AT 

THIS TIME.

Lay out the 12v low voltage cable in the desired location – 
ensure that there is enough cable near the transformer so that 
it can be connected to the transformer without putting strain 
on the plug-in connector.

Connect the individual light units to the cable run using the 
terminal connectors supplied- to determine the limits of the 
cable lengths / possible position of individual LED units. 
NOTE: For additional water ingress protection the connectors 
can be wrapped in a good quality insulation tape.

Once you are satisfied that the lights are positioned correctly 
then they can be fitted into the mounting surface, following 
STEPS 1, 2, and 3 below.

Installation

•  Plan the desired layout of these fittings carefully, 

ensuring the cables will reach the distances between 
the mains plug, the LED driver and each light fitting.

•  Avoid locating any cables in positions that would cause 

a trip hazard. Position cables and driver away from 
areas where they may be at risk from being cut, trapped 

or damaged.

•  The mains plug must be situated indoors. 

•  The LED head units are rated at IP65 and can be 

positioned outdoors. 

•  These fittings should not be installed/mounted in 

concrete.

Kit Layout Diagram

 

10mm hole cut out 

LED lens cover

 

Threaded nut 

STEP 1.

  Remove the 

LED lens cover and 
lower the threaded nut 
down the housing.

STEP 2.

  Drill a 10mm 

hole in the mounting 
surface and push the LED 
housing through it.

STEP 3.

  Replace the 

LED lens cover then 
screw up the threaded 
nut until it secures the 
LED housing in place.