Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Warning
The LED modules are SELV, Class III fittings
and must only be used with the 12v safety plug in
transformer supplied. Under no circumstances must
this transformer be replaced by a standard 13amp
UK type plug. This will cause a safety hazard.
This IP65 rated product is only suitable for connection
to a 240V~50Hz supply in accordance with current IEE
wiring Regulations and should be installed to Part P, UK
Building Regulations and is for Domestic use only.
The LED modules in this set can be fitted into a
bathroom location – zones 1, 2 and outside zones BUT
the transformer has no special protection against the
ingress of water and must ALWAYS be plugged into a dry
location, where there is no danger of it becoming damp.
If the set is to be used outdoors the transformer
must ALWAYS be plugged in indoors.
Do not plug into the mains until your set is fully
assembled.
This range of lights uses non-replaceable LEDs.
When planning a cable run ensure that the low voltage
cable does not run alongside 240v mains cable.
Only use the cable supplied. Although this is low voltage
cable it should be sited such that it is protected against
mechanical damage, for example if it is to be used
outdoors, by incorporating in a trench, of a suitable
depth such that it will avoid any reasonably foreseeable
ground disturbance, and identified by cable covers or with
suitable marking tape etc.
The external flexible cable of this fitting cannot be
replaced; if the cable is damaged, the fitting shall be
destroyed.
If any modification is made it will invalidate the warranty
and may render the product unsafe.
Specification
Power Supply:
220-240V 50Hz. Output: 12V DC 6VA Max. Constant voltage
Lamp:
6 x 0.2W Capsule (Orkney) Cool White
IP rating:
65
Layout
Position the transformer next to the desired (indoor /dry)
socket location – taking note of the length and positioning of
the cable run.
DO NOT PLUG IN THE TRANSFORMER AT
THIS TIME.
Lay out the 12v low voltage cable in the desired location –
ensure that there is enough cable near the transformer so that
it can be connected to the transformer without putting strain
on the plug-in connector.
Connect the individual light units to the cable run using the
terminal connectors supplied- to determine the limits of the
cable lengths / possible position of individual LED units.
NOTE: For additional water ingress protection the connectors
can be wrapped in a good quality insulation tape.
Once you are satisfied that the lights are positioned correctly
then they can be fitted into the mounting surface, following
STEPS 1, 2, and 3 below.
Installation
• Plan the desired layout of these fittings carefully,
ensuring the cables will reach the distances between
the mains plug, the LED driver and each light fitting.
• Avoid locating any cables in positions that would cause
a trip hazard. Position cables and driver away from
areas where they may be at risk from being cut, trapped
or damaged.
• The mains plug must be situated indoors.
• The LED head units are rated at IP65 and can be
positioned outdoors.
• These fittings should not be installed/mounted in
concrete.
Kit Layout Diagram
10mm hole cut out
LED lens cover
Threaded nut
STEP 1.
Remove the
LED lens cover and
lower the threaded nut
down the housing.
STEP 2.
Drill a 10mm
hole in the mounting
surface and push the LED
housing through it.
STEP 3.
Replace the
LED lens cover then
screw up the threaded
nut until it secures the