Thank you for purchasing this light fitting.
Please read the instructions carefully before use to ensure safe and satisfactory operation of this product.
Please retain these instructions for future reference.
Warning
Specification
Installation
Layout
Existing fittings must be completely removed before installation of a new product. Before removing the existing
fitting, carefully note the position of each set of wires.
1. Remove the four screws holding the rim in place and set aside. Remove the glass and reflector and set aside.
Undo the screws holding the housing in position
2. Undo the four self tapping screws holding the cast fitting to the plastic housing. Separate the casting from the
housing by pulling gently. Set the cast fitting aside.
•
Plan the desired layout of this fitting carefully, ensuring the cables will reach the distance between the junction
box and the light fitting.
•
Avoid locating any cables in positions that would cause a hazard. Position cables and outdoor rated junction
boxes (not supplied) away from areas where they may be at risk from being cut, trapped or damaged.
•
We recommend that you use H05RN-F specification cable (not supplied) which is an outdoor grade, rubber
sheathed cable. The mains supply cable must have a minimum cross sectional area of 1.0mm²
•
Cables must be protected using suitable conduit or plastic trunking.
Voltage:
240V 50Hz a.c.
Lamp:
1 x 50W Gu10 Halogen
IP rating:
67
158mm
135mm Diameter
Housing
140mm Diameter
129mm
This is a Class 1 product and must be earthed.
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with IEE Wiring regulations and current Building Regulations.
To prevent electrocution switch off at mains supply before installing or maintaining this fitting. Ensure other persons
cannot restore the electrical supply without your knowledge. If you are in any doubt, please consult a qualified
electrician.
This light fitting should be connected to a circuit with a 30mA RCD fitted.
If replacing an existing fitting, make a careful note of the connections.
This system contains non-replaceable parts and cannot be serviced. If damage occurs the part should be scrapped.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist.
This product cannot be dimmed.
Check with your local authority or retailer for recycling advice.
This product is rated at IP67.
This product is not suitable for location in or near a marine or sea environment.
The entire unit gets hot whilst on for a period of time.
Содержание Aretz GU10 Recessed
Страница 1: ...Aretz GU10 Recessed 7006GU10...