background image

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and 
satisfactory operation of this product. Please retain these instructions for future reference.

Warning

This LED driver is Double Insulated and 
does not require connection to an Earth 
circuit.

Please read these instructions carefully before 
commencing any work. 

This unit must be fitted by a competent and qualified 
electrician.

Install in accordance with IEE Wiring regulations and 
current Building Regulations.

To prevent electrocution switch off at mains supply 
before installing or maintaining this fitting. Ensure 
other persons cannot restore the electrical supply 
without your knowledge.

This light fitting should be connected to a fused circuit.

This LED driver contains non-replaceable parts and 
cannot be serviced. If damage occurs the part should 
be scrapped.

This product cannot be dimmed.

This product is rated at IP20.

Waste electrical products should not be disposed of 
with household waste. Please recycle where facilities 
exist. Check with your local authority or retailer for 
recycling advice.

Specification

Input Voltage 

220V – 240V 50 – 60Hz a.c

Output Voltage 

12W 12V d.c. 1.0A Max Constant Voltage

Cable 

0.75 to 2.5mm squared

Operating Temp  : 

-20˚C to +50˚C

Case Temp (tc)  : 

85˚C

Power Factor 

0.8

Layout

•  Plan the desired layout of this fitting carefully, 

ensuring the cables will reach the distances between 
the LED driver and each LED fitting.

•  Ensure that there is adequate ventilation for the LED 

driver.

•  Avoid locating any cables in positions that would 

cause a hazard. Position cables away from areas 
where they may be at risk from being cut, trapped or 
damaged.

•  Cables that are to be in walls must be protected 

using suitable conduit or plastic trunking.

•  When laying the cables out be aware that voltage 

drop on the low voltage side can be a factor. Use a 
good quality low resistance cable and arrange the 
layout so that the mains cable is the longer length. 
We recommend that a maximum total cable length of 
5.0m is used on the low voltage side.

Existing fittings must be completely removed before 
installation of a new product. Before removing the 
existing fitting, carefully note the position of each set 
of wires
.

•  Position the LED driver next to the mains outlet that 

the system will connect to. Do not connect at this 
stage. Ensure that the LED driver can be accessed 
for any future maintenance requirements.

•  Remove the cover to access the wiring terminals. 

Pay particular attention as to which is mains (PRI) 
and which is the low voltage side (SEC).

•  Connect the low voltage wiring first. Connect the red 

wire to the positive terminal, and the black wire to 
the negative terminal.

•  Ensure that the connections are tight, and that no 

loose strands have been left out of the connection 
block.

•  Connect the mains supply wiring, ensuring that 

brown cable (Live) goes to the L connector and that 
the blue cable (Neutral) goes to the N connector.

•  Ensure that the connections are tight, and that no 

loose strands have been left out of the connection 
block.

•  Replace the cover ensuring that the cable is gripped 

properly.

Direct Wiring

This LED driver is double insulated and must not be 
earthed.

•  The LED Driver can also be fitted to a rewireable 3 

pin plug fitted with a 3 amp fuse. Should the fuse 
require replacement, it must be replaced with a fuse 
rated at 3 amp and approved to BS1362.

•  If the mains plug is unsuitable for the socket outlet 

or is removed for any other reason, then the cut off 
plug should be disposed of safely to prevent the 
hazard of electric shock.

•  There is a danger of electric shock if the cut off plug 

is inserted into any 13 amp socket outlet.

•  The wires in the mains lead on this appliance are 

coloured in accordance with the following code:

  Blue – Neutral

  Brown – Live

•  Use a 3 Amp Fuse approved to BS1362.

E

L

N

Fuse

3 Amps

Cord Clamp

BLUE

Neutral

BROWN

Live

Plug Wiring

Check that...

•  You have correctly identified the wires.
•  The connections are tight.

•  No loose strands have been left out of the connection 

block.