Sawotec ARI WALL HEATER ARI3-45NB WL Скачать руководство пользователя страница 21

ENGLISH

21

A

B

C

Abb 7

Fig. 7

AIR VENTILATIoN

To have a soothing sauna, there should be a proper mixing of hot and cold air inside the sauna 

room. Another reason for ventilation is to draw air around the heater and move the heat to the 

farthest part of the sauna. The positioning of the inlet and outlet vents may vary depending on the 

design of the sauna room or preference of the owner. 

The inlet vent may be installed on the wall directly below the heater (Fig. A). When using the 

mechanical ventilation, the inlet vent may be placed at least 60 cm above the heater (Fig B) or 

on the ceiling above the heater (Fig. C). Through these positions, the heavy cold air that is blown 

into the sauna is mixed with the light hot air from the heater, bringing fresh air for the bathers to 

breathe. The inlet and the outlet vent must have a diameter of 10cm.

The outlet vent should be placed diagonally opposite to the inlet. It is recommended that the outlet 

vent be placed under the platform in a sauna as far as possible from the fresh air vent. It may be 

installed near the floor, or led outside through a pipe from the floor going to a vent to the sauna 

ceiling, or under the door (to the washroom). In this case, the sill slot must be at least 5 cm and 

it is recommended that there is mechanical ventilation in the washroom. The size of the exhaust 

should be twice that of the inlet.   

INSuLATIoN

The sauna must have proper insulation on the walls, ceiling and door. One square meter (m²) of un-

insulated surface increases the cubic volume by approximately 1,2m³ when determining the power 

requirement of the heater. See page 28 (Technical Data).

Ensure that moisture proofing is appropriate in the sauna room. The purpose of this is to prevent 

spreading  of  moisture  to  the  other  rooms  or  wall  structure.  Moisture  proofing  must  be  placed 

between heating insulation and panel.

Thermal and moisture proofing need to be installed according to the following order from outside 

to inside:

The recommended minimum thickness of the thermal insulation in the walls is 50 mm and

in the ceiling 100 mm.

It is possible to use carton or aluminum foil laminate as a vapor barrier, which is affixed

over the insulation aluminum foil inwards.

Leave at least 20 mm air slot between vapor barrier and inside panel

To prevent gathering of the moisture behind the panel, leave the slot between wall panel

and ceiling.

Содержание ARI WALL HEATER ARI3-45NB WL

Страница 1: ...r gratulieren Ihnen zum Kauf eines SAWOTEC Saunaofens Bitte lesen Sie die Bedienungsanleitung vor der Benutzung des Saunaofens sorgf ltig durch ARI3 45NB ARI3 60NB ARI3 75NB ARI3 90NB ARI3 45NS ARI3 6...

Страница 2: ...eitshinweise 4 F r Anwender 4 F r Techniker 6 Ofen Installation 8 Sauna Steine 10 Bef llen des Saunaofens mit Saunasteinen 10 Einstellungen 12 Termostat 12 Zeitschalter 12 Vertauschen von Zeitschalter...

Страница 3: ...into the heater 11 Control settings NB moodels 13 Thermostat 13 Timer 13 Reversible timer and thermostat 14 Electrical diagram 15 Sensor location NS MODELS 18 Resetting over heated thermostat 19 Air...

Страница 4: ...sollten beaufsichtigt werden um sicherzustellen dass sie nicht mit dem Ger t spielen Das Heizger t nicht als Grillofen verwenden Kein Holz auf den Heizk rper legen Heizger t nicht zudecken Feuergefahr...

Страница 5: ...ces should children be allowed to play with the device Do not use the heater as a grill Do not put wood of any kind on the electric heater Do not cover the heater It may cause a fire Do not use the he...

Страница 6: ...er Saunaofen f r ffentliche Saunen oder f r Saunen die durch Fernwirken gestartet werden k nnen verwendet wird muss die T r der Saunakabine mit einer Verriegelung ausgestattet sein sodass die Vorberei...

Страница 7: ...control panel must be mounted outside the sauna cabin If this sauna heater is used for public saunas or saunas that may be switched on by a separate remote control system the door of the sauna room m...

Страница 8: ...Seite Siehe Seite 28 aufgezeigt werden Installieren Sie den Ofen nicht direkt am Boden aufliegend bzw an einer Wandnische Installieren Sie nicht mehr als einen Ofen in der Saunakabine Der Ofen wird se...

Страница 9: ...in heater installations In most countries there is a law that requires heaters to be screwed to the floor The heater gets very hot To avoid the risk of accidental contact with the heater it is recomme...

Страница 10: ...hlen alle Steine vor der ersten Benutzung mit Wasser zu reinigen um etwaige Schmutz oder Staubpartikel zu entfernen welche bei den ersten Verwendungen des Ofens unangenehme Ger che verursachen k nnten...

Страница 11: ...through the heater Load the stones to the heater so that the heating elements are not visible from any angle Larger stones that won t fit between the heating elements must not be forced in place inst...

Страница 12: ...ge Anbringung des Heizger ts oder unzureichende L ftung verursacht sein Beseitigen Sie die Ursache des Problems bevor Sie den Thermostat neu einstellen Die ffnung der Reset Taste ist in der N he des T...

Страница 13: ...sure of the sensor to the glowing heating element may cause sensor to overheat Find out the reason for overheating and fix the problem before resetting the safety sensor The reset button hole is locat...

Страница 14: ...Kn pfe und Ringe 2 L sen Sie die Schrauben der Zeitschaltuhr und des Thermostats 3 Vergewissern Sie sich dass das Loch f r die Reset Taste mit der Taste fluchtet 4 Befestigen Sie das Thermostat mit d...

Страница 15: ...0 3 0 3 0 W V U N G 2 5 2 5 2 5 W V U TERMINAL 1 6 0 kW 4 5 kW TERMINAL 2 U V W U V W G N V U W W V U N G 2 0 kW H1 2 0 kW H2 2 0 kW H3 1 5 kW H4 1 5 kW H5 1 5 kW H6 ARI3 60NS 6 0 kW ARI3 45NS 4 5 kW...

Страница 16: ...H4 2 5 kW H5 2 5 kW H6 TERMINAL 1 6 0 kW 6 0 kW TERMINAL 2 U V W U V W G N V U W W V U N G 2 0 kW H1 2 0 kW H2 2 0 kW H3 2 0 kW H4 2 0 kW H5 2 0 kW H6 Terminal 2 9 0 kw 9 0 kw Terminal 1 G N V U W W...

Страница 17: ...9 0kW ARI3 45NB 4 5kW ARI3 60NB 6 0kW ARI3 75NB 7 5kW ARI3 90NB 9 0kW 3 PHASE 3 PHASE Control of Electric Heating in the household usage is optional Control of Electric Heating in the household usage...

Страница 18: ...from a directional air ventilation which is directed away from sensors Hinweis Bei Verwendung des Saunaofens mit einer ex ternen Steuerung muss der Ofenf hler welcher mit berhitzungsschutz ausgestatte...

Страница 19: ...o overheat If this occurs find out the cause and fix the problem before resetting the safety sensor The reset button is located below the temperature knob berhitzungsschutz r cksetzen Anwendung nur be...

Страница 20: ...schraum vorhanden ist Der Luftauslass sollte doppelt so gro sein wie der Lufteinlass W rmed mmung Die Sauna muss ber eine angemessene W rmed mmung an W nden Decken und an T ren verf gen Ein Quadratmet...

Страница 21: ...ugh a pipe from the floor going to a vent to the sauna ceiling or under the door to the washroom In this case the sill slot must be at least 5 cm and it is recommended that there is mechanical ventila...

Страница 22: ...m n chsten Aufheizen kein Rauch und kein Geruch mehr entstehen k nnen Sie mit dem ersten Saunabad beginnen Wenn erneut Rauch oder Geruch ensteht verlassen Sie sofort die Saunakabine und wiederholen Si...

Страница 23: ...for the first time 4 If no smoke or odor is produced the next time the sauna heater is heated up you can start to use the sauna If smoke or odor is produced again leave the sauna cabin immediately and...

Страница 24: ...en der Sauna B nke Decke Boden und W nde nur warmes Wasser und Mehrzweckreiniger und eine weiche B rste Der Reiniger darf kein Ammoniak oder Chlor enthalten Sp len Sie die Oberfl che mit kaltem Was se...

Страница 25: ...h Wash sauna benches ceiling floor and walls Do not use detergent which includes ammonia or chlorine Rinse surfaces with cold water and ventilate sauna room well If needed protect wood surfaces with w...

Страница 26: ...die Temperatur in der Saunakabine Ist der Hautschalter auf EIN Bei den Ni Modellen befindet sich der Hauptschalter am Boden des Ofens und bei den NS Modellen befindet sich der Hauptschalter an der Sa...

Страница 27: ...re higher than the temperature inside the sauna room Is the main switch ON In Ni models main switch is located at the bottom of the heater and in NS models it is on the power control Are the switchboa...

Страница 28: ...60NS ARI3 75NS ARI3 90NS ARI6 90NB ARI6 90NS ARI6 105NS ARI6 120NS ARI6 150NS ARI6 180NS 380 415V 3N 380 415V 3N 380 415V 3N 380 415V 3N 380 415V 3N 380 415V 3N 380 415V 3N 380 415V 3N 380 415V 3N 380...

Страница 29: ...O ring screw and washer 3 Cable Holder 4 Terminal Block 7 Poles Terminal Block 5 Poles 5 Leveling Bolt 6 Grommet 7 Timer Knob 8 Thermo Knob 9 Timer Switch 10 Thermostat Switch 11 Timer Ring 12 Frame...

Страница 30: ...DEUTSCH ENGLISH 30...

Страница 31: ...DEUTSCH ENGLISH 31...

Страница 32: ...nderungen vorbehalten Subject to change without notice PX 4 ARI_ROUND_3P_ML_DeEn0917...

Отзывы: