18
Installation Instructions
Installing Control Unit
If the control is attached to a
concrete wall, provide a
control holder or equivalent
to mount the control into it.
NOTE
A
B
160 mm
84 mm
Wall
C
OPTIONAL
Interface Holders
Contact your SAWO distributor
Rectangle
Oval
Check the most suitable area to place your steam generator control. The control and the
steam generator should be accessible for the user and maintenance. Do not install the
control unit inside the steam room! The cable of the control is 7.5 meters.
Mount the control in the wall, according to the specifications given below. Follow illustra-
tion.
SAWO Steam Control sets the temperature of your steam room. Mount the steam control
unit on an accessible area outside the steam room. It is recommended not to place the
steam control near to showers or similar wet places.
Never attempt to modify or to fix the steam control. Ask your licensed technician or your
nearest service centre for repair.
Before installation mains supply of the generator must be switch off from the circui breaker.
1.
Press “Power” button for more than 3 seconds.
2.
Press “Standby” button for more than 3 seconds to activate autodrain process, after
which the unit goes automatically off-mode. (If autodrain feature is not available the
unit will go off-mode)
3.
Wait until remaining standby time expires and autodrain process (if available)
completes