Sawo Saunowa 2.0 Скачать руководство пользователя страница 8

ENGLISH

ENGLISH

8

9

Fig. 9

Technical Diagram

RJ Data Cable

5m

1m

For Heaters more than 9 kW 

CONTACTOR UNIT

REMOTE

ON

SWITCH

SAFETY

SWITCH

Heater >9 kW

A

N

N U V W

2,3 kW - 9 kW

Sauna 

Heater

L1

L2

L3

N

PE

Power Supply

PE

Ground

Empty

Fill

U

B

max. 3 kW

max. 2 kW

Combi

Steamer

Steam 

Mate

ank

L vel

T

e

100 W

AC1

100 W

AC1

Light

Fan

T/H Sensor

Sensors

FUS

TS

FUS

TS

1

3

2 4

1

3

2 4

FUS

TS

1

4

TS1

TS2

400V 3N~
50/60Hz

400V 3N~
50/60Hz

Max. 9.0 kW

Saunova 2.0

Interface

TB: 
Co

ntr

ol of He

ating

SAU-UI-V2

EMPTY

SAF

ETY

SESSION

TEMP

SLA

VE

COMBI

1 2 3

BLA
CK

BR

OWN

WHITE

WHITE

BL

UE

BLA
CK

BR

OWN

WHITE

BL

UE

BL

UE

TB

1

1

1

3

2

LIGHT

FAN

FILL

EMPTY

 Note: 

SAFETY

SWITCH

K7

J4

UB

N U

V

W N

N

N N R-in S-in T-in

J3

J2

J1

RS1 F3

F1

F2

RS3

RS2

K6

K5

K4

K2

ERROR

1 2

3

4

K1

K3

REM ON

N

N

N

N

3

4

2

4

REM ON

LEVEL

5 core cable

Control Unit Main Switch

BR

OWN

CONTROL

A

A

BLA
CK

BL

UE

1 1 0 1

Primary 

Supply

Fuse Glass

Light

1000 mA

160 mA

Fuse Glass

Fan & Combi

500 mA

Fuse Glass

SAFETY SWITCH

4

The cable must 

beHO7RN-F type 

or its equivalent.

Optonal

Temperature 

Sensor for 

Bench Area

Temperature 

Sensor with 

Fuse

Optonal

Temperature 

& Humdity 

Sensor for 

Bench Area

Do not connect 

both Optional 

Sensors same 

time. Only one of 

the optional 

sensors at a time 

is allowed.

Optonal

Содержание Saunowa 2.0

Страница 1: ...ENGLISH MANUAL POWER CONTROLLER Not for use in the USA Canada and Mexico ...

Страница 2: ...3 Precautions 3 Power Controller 4 Control Unit to Heater 5 Contactor Unit 6 Sensors 6 Sensor location with heaters mounted on the wall 7 Sensor location with heaters mounted on the floor 7 Technical Diagram 8 Maximum Session Time 10 Fan 10 The Power Controller Main Switch 11 DIP Switch 12 DIP Switch Functions 12 Safety Switch 12 Door Switch 12 Session Time 12 ...

Страница 3: ...alified electrician is allowed to make electrical connections and repairs on the unit Use original parts only 2 Disconnect the Power Controller and the Contactor Unit from the electrical circuit before installation opening the lid of the power controller or contactor unit and repair 3 Check power supply rating before installation 4 Check the correct location of the sensor in the installation secti...

Страница 4: ...rotected against water splashes however it should not get in contact with water Mount the Power Controller in a dry location outside the sauna room Install the Power Controller on the wall in vertical direction only at least 30cm from the ceiling refer to Fig 2 The heater is connected to the electrical network semi stationarily with a H07RN F rubber cable or its equivalent The use of PVC insulated...

Страница 5: ... SAUNA ROOM CABLE INSTALLATION POWER SUPPLY POWER CONTROLLER FLOOR max 800mm from the floor HEATER FLOOR min 600mm OK to install in the surface with moulding Inside the wall RJ cable Insulation Do not installl RJ cable on this area NOTE RJ cable should not be installed inside the sauna room above 70cm from the floor level NOTE Saunova 2 0 user interface can be installed either inside or outside th...

Страница 6: ... to receive more accurate measurements from the sauna room If the heater is mounted on the wall or floor standing less than 200mm from the wall the first temperature sensor needs to be mounted on the wall above the heater Place the sensor 150mm from the ceiling Fig 5 6 However if the heater is more than 200mm from the wall place the sensor to the ceiling over the heater as shown in the figure 7 8 ...

Страница 7: ...1000mm or not under 500mm from air ventilation which is directed away from sensors Sensor Sensor Non directed airflow 360 180 Directed airflow AIR VENT INSTALLATION Min 1000mm Min 500mm CEILING FLOOR WALL WALL WALL Sensor Sensor 150mm See Airvent Installation SENSOR LOCATION Temperature Sensor Air Vent Air Vent Air Vent See Airvent installation Top view Side view Sensor 2 Optional See Airvent Inst...

Страница 8: ...SLAVE COMBI 1 2 3 BLACK BROWN WHITE WHITE BLUE BLACK BROWN WHITE BLUE BLUE TB 1 1 1 3 2 LIGHT FAN FILL EMPTY Note SAFETY SWITCH K7 J4 UB N U V W N N N N R in S in T in J3 J2 J1 RS1 F3 F1 F2 RS3 RS2 K6 K5 K4 K2 ERROR 1 2 3 4 K1 K3 REMON N N N N 3 4 2 4 REM ON LEVEL 5 core cable Control Unit Main Switch BROWN CONTROL A A BLACK BLUE 1 1 0 1 Primary Supply Fuse Glass Light 1000 mA 160 mA Fuse Glass Fa...

Страница 9: ... the pre run time and the session time For public sauna the operating period of the sauna heater can be either 18 or 24 hours Please note if the switches is set to 24 hours it will be ON constantly It needs to be continuously monitored The maximum heater on time is set by the switches on DIP switch in the power controller Figure 11 See also DIP switch session time settings in page 12 Only a qualif...

Страница 10: ...st position switch position I In this switch position all control unit s functions work normally In case of breakdown press the control unit switch on the left part of the rocker to the middle position switch position 0 The unit is now completely switched off In order to switch on the light in the sauna when the unit is switched off press on the left part of the rocker to the second position switc...

Страница 11: ...tch function is available when it is switched ON and Door Switch function when it is OFF Both functions cannot work at the same time Safety Switch The safety switch function is for a triggering device that will cut the heater connection when a combustible foreign object is thrown to the heater Door Switch Install a door sensor and connect it to the control A signal is channel to the control when t...

Страница 12: ... RatedVoltage Switchingcapacity Maximumsaunatemperature forsteameroperation Automaticwaterfilling Rating Rating 3kWAC1 3kWAC1 230V1N 16A 3Phases 16A 1Phase 80 Cor 55 C 230V1N 100WAC1 230V1N 0 5A Optional Description Power Rating Remarks Steamer Depending onthetypeof Sensor2 RatedPower3Phases RatedVoltage3Phases Frequency Switchingcapacityperphase 9kWAC1 3x 3kW 400V3N 50 60Hz 16A Additional Powerex...

Страница 13: ...www sawo com info sawo com Subject to change without notice SAUNOVA_2 0_CONTROLLER_ML_EN_0220 ...

Отзывы: